Maintenance – Flowserve PA46 User Manual
Page 19

9
Replacing stuffing box, valve seat and valve plug PA 46, PA 47
. Undo retaining piece for forkhead
T and pull out hand lever 1. Fig. 3
. Unscrew hexagonhead cap screws
W and remove locking lever A.
3. Remove pressure plate
V and mounting bracket B.
4. Pull out split pin
S.
5. Use openend spanner A. F. 8 mm to unscrew the pressure pin
R from the valve plug D.
6. Remove compression spring
P.
7. Use openend spanner A. F. 3 mm to unscrew the union nut
O.
8. Unscrew sealing plug
G and remove gasket F.
9. Pull out valve plug
D.
0. Take out internal parts
N M L K L J of stuffing box.
. Use steel punch to knock the valve seat
H out of the valve body I. Fig. 7
. Clean stuffing box and valve body.
3. Insert new valve seat
H such that two opposite holes are in the flow direction of the intermittent
valve.
4. Use punch made of CuZn to fix the valve seat in the valve body.
Fig. 8
5. Reinsert valve plug
D and use abrasive paste type TETRABOR
®
F400 for polish grinding.
6. Insert new gasket
F and screw in sealing plug G. Tighten with a torque of 350 Nm.
7. Reinsert internal parts of stuffing box according to order as specified on page 4.
Fig. 5, Fig. 6
8. Apply heatresistance lubricant to stuffing box thread (use e.g. WINIX
®
50).
9. Align valve plug
D such that the hole for the split pin S is perpendicular to the flow direction of the
intermittent valve.
0. Use openend spanner A. F. 3 mm to screw in union nut
O and tighten at room temperature with
a torque of
55 Nm.
. Apply heatresistant lubricant to both sides of the compression spring
P (use e. g. WINIX
®
50)
and place it onto the union nut
O.
. Use openend spanner A. F. 8 mm to screw the pressure pin
R onto the valve plug D until the
holes for the split pin
S in the valve plug and the pressure pin overlap.
3. Insert split pin
S.
4. Put mounting bracket
B and pressure plate V in place. Align check hole C to the right.
5. Insert and screw in hexagonhead cap screws
W and locking lever A and tighten them in
diagonally opposite pairs, applying a torque of
20 Nm.
6. Insert hand lever
1 and fix it to the forkhead T by means of retaining piece 3.
7. Operate valve once (open it until it hits the stop).
WINIX
®
50 is a registered trademark of WINIX GmbH, Norderstedt
TETRABOR
®
is a registered trademark of WackerChemie GmbH, Kempten
Maintenance
continued