Reworking seat flange, Maintenance – Flowserve HV 205 User Manual
Page 23

23
– continued –
Reworking seat flange
If the seating surface of the seat flange is slightly damaged you can remove and rework
the seat flange. For more details see drawing below.
To remove the seat flange please proceed as follows:
Drawing see page 19
1.
Remove body and the actuating cylinder
.
2.
Unscrew the 12 socket-head cap screws
and their associated locking washers
and remove the seat flange. Take out the gasket
.
3.
Unscrew the 6 stay bolts
together with the sleeves
out of the seat flange
.
Re-assembly in reverse order:
Drawing see page 19
1.
First push the sleeves
onto the 6 stay bolts
and screw them with a torque of 25
Nm to the seat flange
. Apply a commerically available lubricant to the screws and
tighten them.
2.
To mount the valve head follow the specified procedure (see page 19).
3.
Then put a new gasket
onto the seat flange
.
4.
Use the 12 socket-head cap screws
together with their locking washers
to
attach the valve head to the mounting flange. Tighten them with a torque of 120 Nm.
Apply a commerically available lubricant to the screws and tighten them in several
steps in diagonally opposite pairs.
D
23
24
6
4
5
7
5
4
7
6
7
23
24
Attention
The specified torques must be strictly observed.
(Ø 85 )
max.5 x 45°
Ra 0.8