4 performance and operating limits – Flowserve FRBHJC User Manual
Page 12

FRBHJC USER INSTRUCTIONS ENGLISH 71569179 11-04
Page 12 of 36
®
3.3.6 Driver 
The driver is normally an electric motor driving via 
couplings, belts, gearboxes, drive shafts etc. 
 
3.3.7 Accessories 
Accessories may be fitted when specified by the 
customer. 
 
3.4 Performance and operating limits
This product has been selected to meet the 
specifications of your purchase order see section 1.5. 
The following data is included as additional information 
to help with your installation. It is typical, and factors 
such as temperature, materials, and seal type may 
influence this data. If required, a definitive statement 
for your particular application can be obtained from 
Flowserve. 
3.4.1 Operating limits
 
Pumped liquid temperature limits 
up to+177 ºC (350 ºF)
Maximum ambient temperature
up to +50 ºC (122 ºF)
Maximum soft solids in suspension
up to 7 % by volume
Maximum pump speed
Refer to the nameplate
3.4.2 Speed torque curves 
To bring a centrifugal pump up to rated speed, the 
driver must be capable of providing more torque at 
each speed than required by the pump. The margin 
between the available and required torque affects the 
time it takes the unit to reach full speed. If the torque 
required by the pump exceeds the torque capability of 
the drive at any run-up speed, the unit will not 
accelerate to full speed. Normally, this is not a problem 
with standard induction or synchronous motors 
provided the proper voltage is supplied at the motor. 
 
For pumps started at shut valve conditions, 100 percent 
full speed torque can be calculated by using the 
formula: 
 
Torque (Nm) = 9545 Shutoff Power (kW) 
 r/min 
 
Torque (lbfx ft) = 5250 Shutoff Power (hp) 
 r/min 
 
Torque required by the pump at any other speed during 
start-up can be determined from the curve above. Note 
that the driver manufacturer usually bases 100 percent 
torque on the design power of the driver and 
consequently the speed-torque curves should be 
plotted in torque units (e.g. Nm) instead of percentage 
torque to avoid confusion. 
 
 
 
 
3.4.3 MAXIMUM WORKING PRESSURES -bar (psi).
CONSTRUCTION
CAST IRON AND C.I.S.S. FITTED
STAINLESS STEEL
316,317L, WORTHITE, ETC.
TEMPERATURE
O
C (
O
F)
UP TO 12”
DISCHARGE
14 TO 16”
DISCHARGE
18 TO 20”
DISCHARGE
UP TO 16”
DISCHARGE
18 TO 20”
DISCHARGE
-30 to 38 (-20 to10 0)
10.3 (150)
10.3 (150)
6.2 (90)
13.8 (200)
8.3 (120)
65 (150)
10.3 (150)
9.7 (140)
6.2 (90)
13.8 (200)
8.3 (120)
95 (200)
10.3 (150)
9.3 (135)
6.2 (90)
13.4 (195)
8.3 (120)
120 (250)
10.3 (150)
9.0 (130)
6.2 (90)
12.6 (185)
8.3 (120)
150 (300)
12.1 (175)
8.3 (120)
175 (350)
CONSULT FACTORY FOR APPLICATIONS IN THIS RANGE.
CASTIRON NOT RECOMMENDED DUE TO THERMAL SHOCK RISKS.
11.0 (160)
7.6 (110)