Figure 4-22
4.6.4.2c Pump stand limitations
In cases where the pump is rigidly mounted by the
pump stand, both the casing limitations and the pump
stand limitations must be satisfied. Due to the limited
load capacity of the pump stands, it may be
necessary to restrain the piping to prevent loads.
a)
Ensure all applied loads are within the allowable
limits of the casing.
b)
Translate the flange loads using the formulae
found in figure 4-24. Dimensional variables S
RS
,
S
RD
and R
S
can be found in figure 4-23.
c)
Calculate F
T
and F
N
using the formulae found in
figure 4-24.
d)
F
T
and F
N
must be less than F
TMAX
and F
NMAX
found in figure 4-25.
e)
F
T
and F
N
must meet the combination formulae
found in figure 4-25.
Figure 4-23: Dimensional data and casing limitations
Dimensions
m (ft)
Allowable casing loads (suction or discharge)
Forces N (lbf)
Moments Nm (lbf•ft)
SD
SRd
SRs
Rs
Fx
Fy
Fz
Mx
My
Mz
2x1.5V-6
0.381
(1.25)
0.191
(0.625)
0.191
(0.625)
0.163
(0.53)
1 824
(410)
17 685
(3 976)
1 824
(410)
692
(510)
976
(720)
692
(510)
2x1.5V-8
0.432
(1.42)
0.229
(0.75)
0.203
(0.67)
0.163
(0.53)
1 601
(360)
17 685
(3 976)
1 601
(360)
692
(510)
976
(720)
692
(510)
3x2V-7
0.432
(1.42)
0.203
(0.67)
0.229
(0.75)
0.163
(0.53)
2 824
(635)
28 147
(6 328)
2 824
(635)
1 120
(900)
1 722
(1 270)
1 120
(900)
3x1.5V-8
0.483
(1.58)
0.226
(0.74)
0.254
(0.83)
0.163
(0.53)
1 601
(360)
17 685
(3 976)
1 601
(360)
692
(510)
976
(720)
692
(510)
2x1.5V-10A
0.483
(1.58)
0.229
(0.75)
0.254
(0.83)
0.197
(0.65)
1 423
(320)
17 685
(3 976)
1 423
(320)
692
(510)
976
(720)
692
(510)
3x2V-10
0.508
(1.67)
0.241
(0.79)
0.267
(0.88)
0.197
(0.65)
2 402
(540)
28 147
(6 328)
2 402
(540)
1 120
(900)
1 722
(1 270)
1 120
(900)
4x3V-10
0.635
(2.08)
0.292
(0.96)
0.343
(1.13)
0.197
(0.65)
2 823
(638)
28 147
(6 328)
2 823
(638)
1 803
(1 330)
2 549
(1 880)
1 803
(1 330)
3x1.5V-13
0.61
(2.00)
0.292
(0.96)
0.318
(1.04)
0.248
(0.81)
1 134
(255)
17 685
(3 976)
1 134
(255)
692
(510)
976
(720)
692
(510)
3x2V-13
0.61
(2.00)
0.292
(0.96)
0.318
(1.04)
0.248
(0.81)
2 002
(450)
28 147
(6 328)
2 002
(450)
1 120
(900)
1 722
(1 270)
1 120
(900)
4x3V-13
0.711
(2.33)
0.33
(1.08)
0.381
(1.25)
0.248
(0.81)
2 535
(570)
28 147
(6 328)
2 535
(570)
1 803
(1 330)
2 549
(1 880)
1 803
(1 330)
6x4V-13
0.762
(2.50)
0.356
(1.17)
0.406
(1.33)
0.248
(0.81)
2 891
(650)
83 195
(18 704)
2 891
(650)
2 210
(1 630)
3 119
(2 300)
2 210
(1 630)
Figure 4-24: Pump stand load translation formulae
Forces
Moments
F
XC
= F
XS
+ F
XD
M
XC
= M
XS
+ M
XD
+ (F
ZS
× SR
S
) - (F
ZD
× SR
D
)
F
YC
= F
YS
+ F
YD
M
YC
= M
YS
+ M
YD
F
ZC
= F
ZS
+ F
ZD
M
ZC
= M
ZS
+ M
ZD
- (F
XS
× SR
S
) + (F
XD
× SR
D
)
TMax
s
zc
yc
s
zc
xc
T
F
R
M
F
R
M
F
F
≤
×
+
+
×
+
=
2
2
707
.
0
707
.
0
MAX
N
s
yc
xc
zc
N
F
R
M
M
F
F
_
707
.
0
≤
+
+
=