MENBLOC USER INSTRUCTIONS ENGLISH 71576296 - 02/13
Page 14 of 40
flowserve.com
MENBLOC with IP55 motor with an added pump
shaft
The reliability of the delivered machine can only be
ensured if it is used according to the conditions
given in this manual. The maximum values specified
in this manual must never be exceeded.
•
Installation maximum altitude
................................................ 1000 m (3281 ft)
•
Maximum working pressure at discharge
................................................... 16 bar (232 psi)
•
Maximum working pressure at suction
................................................... 10 bar (145 psi)
•
Maximum pumped fluid temperature
................................................... 110 °C (230 °F)
•
Minimum pumped fluid temperature
...................................................... -10 °C (14 °F)
•
Maximum ambient temperature
................................................... 40 °C (104 °F)
•
Maximum solid suspension
...................................... 50 g/m
3
(0.003 lbm/ft
3
)
•
Density ....................................1
•
Viscosity ..................................1 mm
2
/s (31 SSU)
•
Frequency .................................................. 50 Hz
•
Maximum rotation speed .................. 1450 min
-1
...................................................... or 2950 min
-1
The maximum speed is shown on the
pump nameplate.