Page 3

5/25/2004
4001-386-01D
!
!
INSTALLATION PLANNING
READ ME FIRST - Mechanical & Electrical Installation Planning Saves Time!
FloScan systems are not difficult to install. Installing one requires only basic electrical & mechanical skills. With forethought and
planning, your system will be installed with few problems.
I. Installation Preparation:
Review the mechanical installation instructions, then survey your vessel. Determine where the Sensor(s), Pulsation Damper(s), (if
used) Switches and Instruments are to be mounted. Place them at their approximate locations. Measure fuel line lengths between
system components, (Primary Filter, Sensor(s), Damper(s), Engine, and Fuel Tank). Determine fitting sizes and type of fittings needed
for each plumbing connection, (JIC, SAE, NPT, NPTF, or Hose Barb).
FloScan Gasoline, “Hi-Flo” system components have ½” Female NPT ports.
FloScan Gasoline, “Lo-Flo” system components have ¼” Female NPT ports.
Review the electrical installation instructions. Open and survey your vessels wire ways and run 3-conductor cables from each sensor
to the instrument. Tachometers require 1 or 2 additional conductors. If there’s an existing tachometer, its signal wires can be used.
II. Mechanical Installation:
Install or mount the Sensor(s), Pulsation Damper(s), (If required) Instruments and Switches, (Reset, MPG, Port/Starboard, Synch).
III. Plumbing:
Mount sensor(s) where they’re to be installed. On installations using Fabric Braid A-1 Fuel Hose install the correct HB X MNPT
fitting into each sensor. Always assemble fittings using a fuel proof pipe thread sealant. Never use Teflon Tape. Use a hose cutter or
knife to cut the fuel hose. Next install the hose onto the barb fittings. Hose should not be twisted, have adequate slack, an ample radius
at all bends and be supported at reasonable distances, approximately 2-4 feet. When clamping hose onto the barbs, use 2 narrow or 1
wide stainless hose clamp on each hose end.
Wire Braid A-1 Aeroquip Type Fuel Hose or Hydraulic Hose: Mount the sensor(s) or sensor assemblies where they’re to be
installed. Mark the hose where it is to be cut. Remove hose and bring it to a hydraulic shop. Have them cut the hose and install hose
ends. Reinstall the hoses and install the correct fitting into each sensor or sensor assembly. Always assemble fittings using a fuel proof
pipe thread sealant. Never use Teflon Tape. Hoses should not be twisted, have adequate slack, an ample radius at all bends and be
adequately supported at reasonable distances, approximately 2-4 feet. AP-50 copper sealing washers, (Connie Seals) or Flaretite seals
may be required to seal JIC & SAE fittings.
IV. Electrical Installation:
Run cables between Sensor(s) and Instrument(s). Cables must be adequately supported at reasonable distances, approximately 2-4
feet. Wire Terminations—Referring to the wiring diagram. Connect Sensor, Instrument and Switches to their respective wires with
crimp type butt or ring connectors. Always cover connectors and wire ends with heat shrink tubing.
V. System Start-Up:
Prime the fuel system and check for leaks. Start and run your engines. Look for leaks and other installation problems. If system is not
operating properly refer to the Troubleshooting Instructions and correct any deficiencies.
VI. Calibration:
When system is running properly, refer to the calibration instructions and calibrate your system.
FloScan Instrument Company, Inc.
Tel: (206) 524-6625 Fax: (206) 523-4961
3016 NE Blakeley Street, Seattle, WA 98105 Email: [email protected] Http://www.floscan.com
- 3FB010U TwinScan GPH/LPH Meter 3FB010U3 TwinScan GPH/LPH Meter 3FB011M1 TwinScan GPH/LPH Meter 3FB011M2 TwinScan GPH/LPH Meter 3FB012U TwinScan GPH/LPH Meter 3FB012U1 TwinScan GPH/LPH Meter 3FB012U2 TwinScan GPH/LPH Meter 3FB013U TwinScan GPH/LPH Meter 3FB013U1 TwinScan GPH/LPH Meter 3FB013U2 TwinScan GPH/LPH Meter 3FB014M2 TwinScan GPH/LPH Meter 3FB015U TwinScan GPH/LPH Meter 3FB015U1 TwinScan GPH/LPH Meter 3FB016M1 TwinScan GPH/LPH Meter 3FB016U TwinScan GPH/LPH Meter 3FB016U1 TwinScan GPH/LPH Meter 3FB016U2 TwinScan GPH/LPH Meter 3FB018M TwinScan GPH/LPH Meter 3FB018M1 TwinScan GPH/LPH Meter 3FB018M2 TwinScan GPH/LPH Meter 3FB022U TwinScan GPH/LPH Meter 3FB022U1 TwinScan GPH/LPH Meter 3FB022U2 TwinScan GPH/LPH Meter 3FB023U TwinScan GPH/LPH Meter 3FB023U1 TwinScan GPH/LPH Meter 3FB028M TwinScan GPH/LPH Meter 3FS012U TwinScan GPH/LPH Meter 3FS012U1 TwinScan GPH/LPH Meter 3FS012U2 TwinScan GPH/LPH Meter 3FS013U TwinScan GPH/LPH Meter 3FS013U1 TwinScan GPH/LPH Meter 3FS013U2 TwinScan GPH/LPH Meter 3FS015U1 TwinScan GPH/LPH Meter 3FS021M TwinScan GPH/LPH Meter 3FS021M1 TwinScan GPH/LPH Meter 3FS022U TwinScan GPH/LPH Meter 3FS022U1 TwinScan GPH/LPH Meter 3FS022U2 TwinScan GPH/LPH Meter 3FS023U TwinScan GPH/LPH Meter 3FS023U2 TwinScan GPH/LPH Meter 3FS023U1 TwinScan GPH/LPH Meter 3FS024M2 TwinScan GPH/LPH Meter 3FS025U TwinScan GPH/LPH Meter 3FS025U1 TwinScan GPH/LPH Meter 3FS026 TwinScan GPH/LPH Meter 3FS026U TwinScan GPH/LPH Meter 3FS026U1 TwinScan GPH/LPH Meter 3FS026U2 TwinScan GPH/LPH Meter 3FS028M TwinScan GPH/LPH Meter 3FS028M1 TwinScan GPH/LPH Meter 3FS028M2 TwinScan GPH/LPH Meter 3FW012U1 TwinScan GPH/LPH Meter 3FW013U2 TwinScan GPH/LPH Meter 3FW016U1 TwinScan GPH/LPH Meter 3FW020U TwinScan GPH/LPH Meter 3FW020U3 TwinScan GPH/LPH Meter 3FW021M TwinScan GPH/LPH Meter 3FW021M1 TwinScan GPH/LPH Meter 3FW021M2 TwinScan GPH/LPH Meter 3FW022U TwinScan GPH/LPH Meter 3FW022U1 TwinScan GPH/LPH Meter 3FW022U2 TwinScan GPH/LPH Meter 3FW023U TwinScan GPH/LPH Meter 3FW023U1 TwinScan GPH/LPH Meter 3FW023U2 TwinScan GPH/LPH Meter 3FW024M TwinScan GPH/LPH Meter 3FW024M2 TwinScan GPH/LPH Meter 3FW025U TwinScan GPH/LPH Meter 3FW025U1 TwinScan GPH/LPH Meter 3FW025U3 TwinScan GPH/LPH Meter 3FW026U TwinScan GPH/LPH Meter 3FW026U1 TwinScan GPH/LPH Meter 3FW026U2 TwinScan GPH/LPH Meter 3FW028M1 TwinScan GPH/LPH Meter 3FW028M2 TwinScan GPH/LPH Meter 3FW028M4 TwinScan GPH/LPH Meter 3FS018M2 TwinScan GPH/LPH Meter