CALIBRATION

TwinScan

®

3” GPH Instrument

Gasoline and Diesel Engines

To ensure years of trouble free operation of your new GPH Meter,

please read all of these instructions carefully before beginning your installation.


Calibration and flow sensor selection of your TwinScan

®

3” GPH Instrument is done with the sixteen position rotary switches on the

back of the instrument. The RED switch is used for sensor type and pointer damping selection; the BLACK switch is used to calibrate
your instrument. It is critical that you set the sensor selection switch correctly. Before re-calibrating your instrument, note the current
position of the switch and check the calibration table for the correct flow sensor selection. Changing the totalizer calibration also
changes the analog needle calibration.

Re-calibration is required only if you find your totalizer reading to be more than 2% different from the actual fuel put into the tank.
Various things such as the attitude of the boat in the water, the amount of the fill up, and how full the tank is filled affect accuracy.
The larger the amount of fuel you base calibration on, the more accurate your system will be.

To check the calibration:

1. Fill the tank(s) and reset the totalizer to zero.

2. Operate the boat in a normal manner until you would ordinarily refuel.

3. Fill the tank(s) as close to the same level as possible. Check the amount of fuel the tank actually took as well as the amount the

totalizer shows you used. In most cases, these two amounts are within 2% of each other and no additional calibration is
required.


4. To change the calibration, rotate the BLACK switch on the back of the instrument until the totalizer reads as close to your

actual fill up as possible. If your reading is off by more than you can calibrate, go to the troubleshooting guide.


BLACK Switch

Effect to Totalizer

RED Switch

Sensor Results

0 No

Change

0

20B

Light meter damping

1 +2%

1

20B

Heavy meter damping

2 +4%

2

20B

Light meter damping

3 +6%

3

20B

Light meter damping

4

+8%

4

231

Light meter damping

5

+10%

5

231

Heavy meter damping

6

-20%

6

231

Light meter damping

7

-18%

7

231

Light meter damping

8 -16%

8

233C

Light meter damping

9 -14%

9

233C

Heavy meter damping

A -12%

A

233C

Light meter damping

B -10%

B

233C

Light meter damping

C

-8%

C

w/diesel*

Light meter damping

D

-6%

D

w/diesel*

Heavy meter damping

E

-4%

E

w/diesel*

Light meter damping

F

-2%

F

w/diesel*

Light meter damping

*TwinScan + MFI combination