TROUBLESHOOTING
TwinScan
®
3” Instrument - Gallons Per Hour (LCD)
BEFORE CALLING FOR ASSISTANCE, COMPLETE THESE TROUBLESHOOTING CHECKS AND RECORD YOUR
FINDINGS. TECHNICAL SUPPORT REQUIRES THIS INFORMATION BEFORE A RETURN AUTHORIZATION WILL BE
ISSUED. IT TAKES ABOUT 20 MINUTES AND IS VERY IMPORTANT IN ANALYZING SYSTEM PROBLEMS.
Before starting, record instrument model number and switch settings.
MODEL # _____________________
SERIAL # ____________
RED SWITCH POSITION __________
BLACK SWITCH POSITION _________
Perform the Instrument Diagnostic & Duty Cycle Tests outlined in Sections I & II First. Record your findings.
I. INSTRUMENT DIAGNOSTIC SELF-TEST
• Secure power to the Red, and Red/White wires, (Turn both key switches OFF).
• Turn power on, (Either to one or both switches). At start-up, the instrument automatically performs a, “Self-test”.
• Verify that the pointer’s back-lighting glows Red, and that the LCD back-light is glowing Green.
• Observe that the pointers smoothly sweep to near full scale, (Slightly above or below) then smoothly drop back to zero.
The LCD display shows the following numbers and letters in sequence. These are examples, actual readings may vary. Switch settings
and configurations are shown on the LCD as, “0123456789AbCdEF”.
8.8.8.8 LCD segment and back-lighting check.
1.21
Software version number.
F 3
Red, (Port) and Black (Starboard) switch settings.
- - 34
Internal configuration (scale range, units, etc.)
Blank
123.4
Current total gallons or total liters, (Indicates normal operation).
• Record the software version __________ and switch settings _____ _____. FloScan Technical Support will ask for these.
The self-test verifies adequate power, a good ground, that the pointers move, and the LCD display is working.
If the self-test fails, the LCD shows, “PO” plus a two-digit number code. The pointers also show the error number as a, “Blink Code”.
Sitting near center scale the pointers will twitch upwards, showing a numeric value. For Po23 the pointers twitch twice, pause for a
moment, and then twitch three times. After a long wait the twitching resumes. This continues until power is secured. If the self-test
fails, verify that supply voltage is at least 10 VDC. If voltage drops below 10V, the self-test may fail.
II. DUTY CYCLE TEST
• Start both engines and run at idle.
• Close and open the RESET switch twice within 0.6 seconds—like double-clicking a computer mouse.
• The LCD will show dcy when it’s in duty cycle check mode.
• With the display showing dcy the pointers should remain steady and in the middle third of their scales.
• At very low flow rates, the pointers track the on/off signal from each sensor and will wiggle.
• Increase engine rpm until the pointers are steady.
• Steady readings with occasional, “Hick-ups” may indicate air or vapor bubbles passing through the sender.
• “Double-click” the RESET switch to return to the normal fuel flow display mode.
- 3FB010U TwinScan GPH/LPH Meter 3FB010U3 TwinScan GPH/LPH Meter 3FB011M1 TwinScan GPH/LPH Meter 3FB011M2 TwinScan GPH/LPH Meter 3FB012U TwinScan GPH/LPH Meter 3FB012U1 TwinScan GPH/LPH Meter 3FB012U2 TwinScan GPH/LPH Meter 3FB013U TwinScan GPH/LPH Meter 3FB013U1 TwinScan GPH/LPH Meter 3FB013U2 TwinScan GPH/LPH Meter 3FB014M2 TwinScan GPH/LPH Meter 3FB015U TwinScan GPH/LPH Meter 3FB015U1 TwinScan GPH/LPH Meter 3FB016M1 TwinScan GPH/LPH Meter 3FB016U TwinScan GPH/LPH Meter 3FB016U1 TwinScan GPH/LPH Meter 3FB016U2 TwinScan GPH/LPH Meter 3FB018M TwinScan GPH/LPH Meter 3FB018M1 TwinScan GPH/LPH Meter 3FB018M2 TwinScan GPH/LPH Meter 3FB022U TwinScan GPH/LPH Meter 3FB022U1 TwinScan GPH/LPH Meter 3FB022U2 TwinScan GPH/LPH Meter 3FB023U TwinScan GPH/LPH Meter 3FB023U1 TwinScan GPH/LPH Meter 3FB028M TwinScan GPH/LPH Meter 3FS012U TwinScan GPH/LPH Meter 3FS012U1 TwinScan GPH/LPH Meter 3FS012U2 TwinScan GPH/LPH Meter 3FS013U TwinScan GPH/LPH Meter 3FS013U1 TwinScan GPH/LPH Meter 3FS013U2 TwinScan GPH/LPH Meter 3FS015U1 TwinScan GPH/LPH Meter 3FS021M TwinScan GPH/LPH Meter 3FS021M1 TwinScan GPH/LPH Meter 3FS022U TwinScan GPH/LPH Meter 3FS022U1 TwinScan GPH/LPH Meter 3FS022U2 TwinScan GPH/LPH Meter 3FS023U TwinScan GPH/LPH Meter 3FS023U2 TwinScan GPH/LPH Meter 3FS023U1 TwinScan GPH/LPH Meter 3FS024M2 TwinScan GPH/LPH Meter 3FS025U TwinScan GPH/LPH Meter 3FS025U1 TwinScan GPH/LPH Meter 3FS026 TwinScan GPH/LPH Meter 3FS026U TwinScan GPH/LPH Meter 3FS026U1 TwinScan GPH/LPH Meter 3FS026U2 TwinScan GPH/LPH Meter 3FS028M TwinScan GPH/LPH Meter 3FS028M1 TwinScan GPH/LPH Meter 3FS028M2 TwinScan GPH/LPH Meter 3FW012U1 TwinScan GPH/LPH Meter 3FW013U2 TwinScan GPH/LPH Meter 3FW016U1 TwinScan GPH/LPH Meter 3FW020U TwinScan GPH/LPH Meter 3FW020U3 TwinScan GPH/LPH Meter 3FW021M TwinScan GPH/LPH Meter 3FW021M1 TwinScan GPH/LPH Meter 3FW021M2 TwinScan GPH/LPH Meter 3FW022U TwinScan GPH/LPH Meter 3FW022U1 TwinScan GPH/LPH Meter 3FW022U2 TwinScan GPH/LPH Meter 3FW023U TwinScan GPH/LPH Meter 3FW023U1 TwinScan GPH/LPH Meter 3FW023U2 TwinScan GPH/LPH Meter 3FW024M TwinScan GPH/LPH Meter 3FW024M2 TwinScan GPH/LPH Meter 3FW025U TwinScan GPH/LPH Meter 3FW025U1 TwinScan GPH/LPH Meter 3FW025U3 TwinScan GPH/LPH Meter 3FW026U TwinScan GPH/LPH Meter 3FW026U1 TwinScan GPH/LPH Meter 3FW026U2 TwinScan GPH/LPH Meter 3FW028M1 TwinScan GPH/LPH Meter 3FW028M2 TwinScan GPH/LPH Meter 3FW028M4 TwinScan GPH/LPH Meter 3FS018M2 TwinScan GPH/LPH Meter