08/20/2004

4001-102-00I

FloScan Instrument Company, Inc.

Tel: (206) 524-6625

Fax: (206) 523-4961

3016 NE Blakeley Street, Seattle, WA 98105

Email:

[email protected]

Http://www.floscan.com

5. In, “Diagnostic Mode” the totalizer will count at 1 gallon or 1 liter per second. If it does not, the

Instrument is defective.

6. With the BLUE wire floating, (Disconnected) on single engine systems, or the Port/Starboard select switch set to Port on

twin engine systems, the pointer should read approximately:

5 GPH models

4.5

20 LPH models

18

10 GPH models

9

40 LPH models

35

20 GPH models

18

80 LPH models

70

32 GPH models

28

160 LPH models

140

50 GPH models

45

500 LPH models

450

100 GPH models

90

7.

With the

BLUE wire connected to the Instruments’ BLACK wire on single engine systems, or the Port/Starboard select switch set to
Starboard on twin engine systems, the pointer should read approximately:

5 GPH models

0.25

20 LPH models

1

10 GPH models

0.5

40 LPH models

2

20 GPH models

1

80 LPH models

5

32 GPH models

2

160 LPH models

10

50 GPH models

2

500 LPH models

20

100 GPH models

5

NOTE: If readings are significantly Higher or Lower, the Instrument may be defective.

8. Turn switches 1, 2, 3, 4, 5, 8 and 9 OFF, leave 6 and 7 ON.

9. Disconnect the WHITE and BROWN wires at the Instrument. Connect a course thread, (½ - 13) or similar non-plated bolt to

the BLACK wire.

10. With the BLUE wire floating, (Disconnected) or Port/Starboard select switch set to Port, vigorously run the WHITE wire up

and down the bolt threads. This generates a pulse and should lift the needle off zero. The totalizer should also eventually start
counting. Faster movements give higher readings.

11. With the BLUE wire connected to ground or the Port/Starboard select switch set to Starboard, vigorously run the BROWN

wire up and down the threaded bolt as described above. This generates a pulse and should lift the needle off zero. The
totalizer should also eventually start counting. Faster movements give higher readings.

12. If the Instrument passes steps 10 & 11, return switches 1-9 to their original position, and proceed with Part II. If not contact

FloScan Technical Support.

NOTE: Occasionally a good Instrument will fail the, (Bolt Scratch Test).

II. TEST FLOW SENSOR(S)

1. With your voltmeter set to a DC scale greater than 14 volts, measure between the RED (+12VDC) and

BLACK (Instrument ground) wires. With engine idling, measure and record the voltage reading.

___________VDC

2. Move the voltmeters’ negative lead to the WHITE (Signal) wire. With engine idling, measure and record

the voltage reading. Readings between 4 and 10 VDC, usually indicate a good sensor.

___________VDC

3. Stop the engine while observing the voltmeter. Readings should fluctuate between a high of 9 to 12 VDC,

and a low of 0 to 4 VDC as the sensors’ turbine slows to a stop.

___________VDC

NOTE: This may not be seen on a digital voltmeter.