9. Why isn’t my totalizer as accurate as it could be?

The major causes of inaccurate totalizer readings are:

• Air bubbles in the fuel line caused by vacuum leaks around fuel filter gaskets, and/or improperly sealed plumbing joints.

• Incorrect flow sensor installation.

• Installing sensor within 12-14” of the fuel pump.

• Faulty wiring.

• Improper sensor selection and instrument calibration.

10. What do I do if I have a problem?

Most problems are related to improper installation. Step 1 is to review the installation and verify that system components are installed
and wired correctly. Next follow the troubleshooting guide, and record your results. This will most likely lead you to the problem. If
not please call FloScan Technical Support at (800 522-3610) with your test findings. If you did not complete the troubleshooting steps,
you will be asked to do so before calling back.