Fire Magic Combustible Overhead Protection Kit User Manual
Combustible overhead protection kit, For built-in gas grills only)

1
REV 0 - 1502191200
L-C2-468
INSTALLER:
Leave these instructions with consumer.
CONSUMER:
Retain for future reference.
ROBERT H. PETERSON CO. • 14724 East Proctor Avenue • City of Industry, CA 91746
Grill Series
Kit model #
Kit
Dimensions
Fire Magic
AOG
A530i, A430i,
C430i
24(N,P)B
36-COPK
47.5"w x 37.5"d
E660i, A660i,
A540i, C540i
30(N,P)B
42-COPK
53.5"w x 37.5"d
E790i, A790i
36(N,P)B
48-COPK
59.5"w x 37.5"d
E1060i
--
60-COPK
71.5"w x 37.5"d
If your model is not listed:
Measure your grill oven hood from left to right. Add 10”.
This calculation should be equal to or less than the
number found in the appropriate kit model.
Example: Grill width 30"+10"= 40". KIT: 42-COPK.
Table 1 - Kit models
COMBUSTIBLE OVERHEAD
PROTECTION KIT
(For built-in gas grills only)
This protection kit meets the RHP requirement when a
Fire Magic / AOG grill is installed 6' below an overhead
combustible construction.
Note: A vent hood is not required if this kit is used.
IMPORTANT INFORMATION
I n s t a l l a t i o n mu s t b e p e r fo r m e d by a q u a l i f i e d
professional service technician.
INSTALLATION REQUIRES TWO OR MORE PEOPLE.
EXERCISE EXTREME CARE DURING INSTALLATION.
Read these instructions and the safety and installation
sections of the grill owner's manual before beginning this
protection kit installation.
CLEARANCE REQUIREMENTS
Overhead construction:
Any combustible overhead contruction must be a minimum of
6 feet above the grill countertop. This clearance must include
any additional material used for mounting and/or covering
the protection kit. See Fig. 1-1 and the INSTALLATION
section of this instruction for details.
Rear wall:
The rear wall must be constructed of non-combustible
material and must be between 4-6" from the rear of the
grill. See Fig. 1-1.
Fig. 1-1 Clearance requirements
(Echelon Diamond
grill shown)
Any combustible overhead construction must
be a minimum of 6' above the countertop.
(Countertop)
Non-combustible
rear wall
Min.
6'
Must be
between 4-6"
Continued on next page
(36-COPK protection kit shown)