PLANNING FOR INSTALLATION
With our insulating liner, you can safely install the Fire Magic
barbecue in a wood cabinetry, stucco, or other combustible
enclosure.
Do not install this unit under unprotected fl ammable
surfaces. Do not install or use this appliance inside a
building, garage, or any other enclosed area, including
recreational vehicles or boats.
Note:
This barbecue must be installed so that it can
be removed in the event service should be
necessary. Any protrusion into the barbecue
enclosure from either side, which is less than
11
1
/
4
" (28.2 cm) below the countertop, may
obstruct the frame and prevent the unit from
dropping into place.
ENSURING PROPER COMBUSTION AIR AND
COOLING AIR FLOW
The
1
/
2
" (1.27 cm) vent space between the top panel of the
unit and the countertop that is created by the attached cork
mounting pads resting on the countertop must be left clear.
Blockage of barbecue air fl ow causes overheating and poor
combustion. A vent screen is provided to cover this opening.
ELECTRICAL OUTLETS
Electrical outlets in the vicinity of the barbecue, which might
be used for rotisserie motors or other appliances, must be
properly grounded.
Note:
Keep electrical supply cords away from all heated
surfaces.
EXHAUST REMOVAL
If installed under a patio roof, the cooking grid area must be
fully covered by a chimney and exhaust hood. An exhaust fan
with a rating of at least 1,000 CFM (472 liters per second) or
more may be necessary to effi ciently remove smoke and other
cooking by-products from the covered area. Do not install in
a fully enclosed area of any kind.
GAS SUPPLY PLUMBING REQUIREMENTS
Rigid 1
1
/
2
" (1.27 cm) black steel pipe is required to conduct
the gas supply into the barbecue enclosure for connection
to the unit. Pipe joint compound that is resistant to all gasses
should be applied to all male fi ttings and all joints tightened
securely. Do not use pipe joint compound to connect fl are
fi ttings.
The pipe should terminate near the front and center of the
enclosure, no more than 5" (12.7 cm) from the countertop.
Installation will be simplifi ed if the pipe enters the enclosure
vertically from the bottom, at least 6" (15.2 cm) in from each
WHERE TO INSTALL THE BARBECUE
Fire Magic barbecues are designed for outdoor use only.
Drop-in models must be installed in masonry or other
type of fi reproof surroundings. This unit is not insulated
and must be installed with a clearance from combustible
materials of 18" (45.7 cm) on the sides and the back. This
appliance shall not be located under unprotected overhead
combustible construction.
Fig. 4-2
- View from left
Countertop
Rear
Front
12" Max
9" Max
5" Max
8" Max
WARNING
CAUTION: Wind blowing into or across the rear oven lid vent
can cause poor performance and/or dangerous
overheating. Orient the
grill so that the prevailing
wind blows toward the
front of the grill (Fig. 4-3).
CAUTION: To prevent dangerous
overheating, the rear
of the unit must have a
minimum clearance of 8”
from any backsplash/wall.
DRIP TRAY ACCESS
If the grill is being installed next to the left wall of the enclosure,
a 6" (15.3cm) clearance from the left wall (or any appliances)
is required to properly remove the drip trays through the top
of the unit. See the BARBECUE SAFETY INFORMATION &
MAINTENANCE section for installation/removal.
Fig. 4-3
CORRECT
Place grill so prevailing wind
blows toward front of grill
Fig. 4-1
- Top view
Vertical pipe up against front
Stub out gas pipe anywhere in
this area
Top view
Back
6"
6"
12"
24
1
/
4
"
19
1
/
4
"
side, and within 8" (20.3 cm) of the front wall (
Fig. 4-1
).
If the pipe does not come up against the front wall, it can
easily be run along the enclosure fl oor and turned up to rise
within 5" (12.7 cm) of the countertop, tight against the front
wall (leaving space only to connect fi ttings,
Fig. 4-2
).
Note: A
n external valve in the gas line is necessary for
safety when the barbecue is not in use. It also
provides for convenient maintenance and repair.
A removable key is recommended.
GAS SUPPLY AND MANIFOLD PRESSURE:
For natural gas - Normal 7" (17.8 cm) w.c. (water column),
minimum 5" (12.7 cm), maximum 10
1
/
2
" (26.7 cm).
For propane gas - Normal 11" (27.9 cm) w.c., minimum 8" (20.3
cm), maximum 13" (33 cm).
6"