5

TOP VIEW

(Countertop)

Lower support

Countertop

overhang

Control

panel

ENCLOSURE

CUT-OUT

DIMENSIONS

Fig. 5-1

FRONT VIEW

B

C

D

See next page

for substrate

considerations

Countertop

overhang

X

TOP VIEW

SIDE VIEW

Countertop

overhang

(Control

panel)

(Countertop)

Y

1

/

4

"

Clearance

(Overhang)

X=

5

/

8

"

Y= Total
Countertop
Overhang

A

Control

panel

Check

clearance for

control panel

removal

*

Note:

If installing this unit in a combustible enclosure, the correct insulating liner must be used. Consult liner
instructions for counter cut-out dimensions and installation.

† Includes any substrate at front wall of enclosure (in the area the rear of the control panel is to sit fl ush against). See

SUBSTRATE section on next page.

‡ Only applicable for non-combustible enclosures that have countertops with an overhang (see illustration and section

below).

COUNTERTOP OVERHANG

The control panel is designed to sit fl ush against the enclosure front wall. If the non-combustible enclosure countertop extends beyond
the front wall, creating a countertop overhang, it must be cut fl ush with the front wall for the width of the control panel or a gap will be
created exposing the forward portions of the left and right side fi re walls of the unit. See illustrations above.

Important:

FOR YOUR SAFETY, you must provide openings in the island enclosure for drainage, replacement air, and cross-
ventilation of any storage area exposed to possible leakage from gas connections, the unit, or propane tanks. See the
ENCLOSURE REQUIREMENTS section for details.

MODEL SPECIFICATIONS

REV 2 - 1502100955

L-C2-379

MODEL SPECIFICATIONS TABLE

Table 1

Main burner N/P orifi ce drill size

#49 / #56

Fire Magic insulating liner model # (not included)*

3278-51

Input electrical requirements

120VAC / 15 AMP minimum / 60 Hz / GFCI outlet

A Countertop to unit bottom cut-out*

12"

B Side to side cut-out*

19"

C Front to back cut-out*†

18-

3

/

4

"

D Control panel width cut-out

20-

1

/

4

"