beautypg.com

Installation conditions, Ecofilm set – floor heating film, 5 m long – Fenix ECOFILM SET User Manual

Page 3: 230 volts

background image

3

ECOFILM SET

Total output Length of film strip

Resistance

Total film width Active heating film

TYPE

[W]

[m]

[Ω]

[m]

width [m]

Eset 60 - 0,6x1,5m/ 50W

50

1,5

1058

0,6

0,55

Eset 60 - 0,6x2m / 66W

66

2

801,5

0,6

0,55

Eset 60 - 0,6x2,5m/ 83W

83

2,5

637,3

0,6

0,55

Eset 60 - 0,6x3m/ 99W

99

3

534,3

0,6

0,55

Eset 60 - 0,6x4m/ 132W

132

4

400,8

0,6

0,55

Eset 60 - 0,6x5m/ 165W

165

5

320,6

0,6

0,55

Eset 60 - 0,6x6m/ 198W

198

6

267,2

0,6

0,55

Eset 60 - 0,6x8m/ 264W

264

8

200,4

0,6

0,55

Eset 60 - 0,6x10m/330W

330

10

160,3

0,6

0,55

Eset 80 - 0,6x1,5m/ 66W

66

1,5

801,5

0,6

0,55

Eset 80 - 0,6x2m/ 88W

88

2

601,1

0,6

0,55

Eset 80 - 0,6x2,5m/ 110W

110

2,5

480,9

0,6

0,55

Eset 80 - 0,6x3m/ 132W

132

3

400,8

0,6

0,55

Eset 80 - 0,6x4m/ 176W

176

4

300,6

0,6

0,55

Eset 80 - 0,6x5m/ 220W

220

5

240,5

0,6

0,55

Eset 80 - 0,6x6m/ 264W

264

6

200,4

0,6

0,55

Eset 80 - 0,6x8m/ 352W

352

8

150,3

0,6

0,55

Eset 80 - 0,6x10m/ 440W

440

10

120,2

0,6

0,55

Eset 80 - 1,0x1,5m/ 117W

117

1,5

452,1

1

0,97

Eset 80 - 1,0x2m/ 156W

156

2

339,1

1

0,97

Eset 80 - 1,0x2,5m/ 195W

195

2,5

271,3

1

0,97

Eset 80 - 1,0x3m/ 234W

234

3

226,1

1

0,97

Eset 80 - 1,0x4m/ 312W

312

4

169,6

1

0,97

Eset 80 - 1,0x5m/ 390W

390

5

135,6

1

0,97

Eset 80 - 1,0x6m/ 468W

468

6

113

1

0,97

Eset 80 - 1,0x8m/ 624W

624

8

84,8

1

0,97

Eset 80 - 1,0x10m/ 780W

780

10

67,8

1

0,97

Supply density

[W/m

2

]

60
60
60
60
60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80

ECOFILM SET – Floor Heating Film

The heating film includes two SK AV connecting cables 1.5 mm

2

, 5 m long

230 Volts


1. Installation

Conditions

Other use of the heating foil or other placement of the heating foil

than is mentioned in these instructions can be hazardous to health

and life or can cause material damage. Warranty conditions do not

apply to such use.

The heating foil is designed for dry- process laying; it isn’t glued but

it must be fixed to prevent moving/slipping beyond the nonheating

edges.

The heating film must not be installed on irregular surfaces. The

heating film must be protected against damage during installation

(e.g. damage of insulation with sharp objects, walking in unsuitable

footwear etc.). It is only possible to walk in shoes with a soft sole on

the heating film placed on a flat and smooth surface.