Installation conditions, Ecofilm set – floor heating film, 5 m long – Fenix ECOFILM SET User Manual
Page 3: 230 volts

3
ECOFILM SET
Total output Length of film strip
Resistance
Total film width Active heating film
TYPE
[W]
[m]
[Ω]
[m]
width [m]
Eset 60 - 0,6x1,5m/ 50W
50
1,5
1058
0,6
0,55
Eset 60 - 0,6x2m / 66W
66
2
801,5
0,6
0,55
Eset 60 - 0,6x2,5m/ 83W
83
2,5
637,3
0,6
0,55
Eset 60 - 0,6x3m/ 99W
99
3
534,3
0,6
0,55
Eset 60 - 0,6x4m/ 132W
132
4
400,8
0,6
0,55
Eset 60 - 0,6x5m/ 165W
165
5
320,6
0,6
0,55
Eset 60 - 0,6x6m/ 198W
198
6
267,2
0,6
0,55
Eset 60 - 0,6x8m/ 264W
264
8
200,4
0,6
0,55
Eset 60 - 0,6x10m/330W
330
10
160,3
0,6
0,55
Eset 80 - 0,6x1,5m/ 66W
66
1,5
801,5
0,6
0,55
Eset 80 - 0,6x2m/ 88W
88
2
601,1
0,6
0,55
Eset 80 - 0,6x2,5m/ 110W
110
2,5
480,9
0,6
0,55
Eset 80 - 0,6x3m/ 132W
132
3
400,8
0,6
0,55
Eset 80 - 0,6x4m/ 176W
176
4
300,6
0,6
0,55
Eset 80 - 0,6x5m/ 220W
220
5
240,5
0,6
0,55
Eset 80 - 0,6x6m/ 264W
264
6
200,4
0,6
0,55
Eset 80 - 0,6x8m/ 352W
352
8
150,3
0,6
0,55
Eset 80 - 0,6x10m/ 440W
440
10
120,2
0,6
0,55
Eset 80 - 1,0x1,5m/ 117W
117
1,5
452,1
1
0,97
Eset 80 - 1,0x2m/ 156W
156
2
339,1
1
0,97
Eset 80 - 1,0x2,5m/ 195W
195
2,5
271,3
1
0,97
Eset 80 - 1,0x3m/ 234W
234
3
226,1
1
0,97
Eset 80 - 1,0x4m/ 312W
312
4
169,6
1
0,97
Eset 80 - 1,0x5m/ 390W
390
5
135,6
1
0,97
Eset 80 - 1,0x6m/ 468W
468
6
113
1
0,97
Eset 80 - 1,0x8m/ 624W
624
8
84,8
1
0,97
Eset 80 - 1,0x10m/ 780W
780
10
67,8
1
0,97
Supply density
[W/m
2
]
60
60
60
60
60
60
60
60
60
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
80
ECOFILM SET – Floor Heating Film
•
The heating film includes two SK AV connecting cables 1.5 mm
2
, 5 m long
•
230 Volts
1. Installation
Conditions
•
Other use of the heating foil or other placement of the heating foil
than is mentioned in these instructions can be hazardous to health
and life or can cause material damage. Warranty conditions do not
apply to such use.
•
The heating foil is designed for dry- process laying; it isn’t glued but
it must be fixed to prevent moving/slipping beyond the nonheating
edges.
•
The heating film must not be installed on irregular surfaces. The
heating film must be protected against damage during installation
(e.g. damage of insulation with sharp objects, walking in unsuitable
footwear etc.). It is only possible to walk in shoes with a soft sole on
the heating film placed on a flat and smooth surface.