socket. This socket must be easily ac-

cessible after the installation so that the

extractor hood can be disconnected
from the power supply if necessary. If a

fixed connection is used (e.g. if a suit-

able wall socket is not available), the

extractor hood may only be connected
by a qualified electrician. For fixed con-

nections, the extractor hood must be

connected to a single power circuit fitted

with an isolating device. Isolating de-
vices include switches with a contact

gap of at least 3 mm and all-pole

switches, e.g. circuit breakers and con-

tactors. Before working on the electrical
connection of the extractor hood com-

mences, the mains circuit/circuits must

be switched off. Before drilling the

mounting holes, make sure that no elec-
trical cables can be damaged during

drilling. The electrical connection must

be prepared in such a way as to allow

the easy connection of the extractor
hood. Local regulations must be ob-

served.

Exhaust air ducting (for extraction mode)

Exhaust kitchen air must not be ducted

into a chimney flue that is also used for

the exhaust air from devices using fuels

(e.g. gas). Official regulations regarding
ducting of exhaust air must be observed.

The exhaust air path must be prepared

in such as way as to allow the easy con-

nection of the extractor hood. The ex-
haust air hose must not have any kinks.

If the extractor hood is operated in ex-

traction mode at the same time as other

room-air-dependent fire appliances (e.g.
wood, gas, oil or coal-fired appliances)

in the same room, lethal combustion

gases may be directed back into the

room due to the resulting negative pres-
sure. The operator must therefore pro-

vide a sufficient air supply at all times.

The negative pressure in the room must

not exceed 4 Pa (0.04mbar).

Installation instructions

Solid fuel appliances

The installation of the extractor hood

above solid fuel appliances, which can
pose a fire hazard, (e.g. flying sparks) is

only permissible if the solid fuel appli-

ance is equipped with a sealed, non-

removable cover.


We reserve the right to make technical
changes.