beautypg.com

Operating heater – Desa CBN20T EN User Manual

Page 15

background image

www.desatech.com

107882-01K

15

OF

F

PIL

OT

5. Turn control knob counterclockwise

to the PILOT position. Press in control

knob for five (5) seconds (see Figure 19).

Note:

You may be running this heater for

the first time after hooking up to gas sup-

ply. If so, the control knob may need to be

pressed in for 30 seconds or more. This will

allow air to bleed from the gas system.

• If control knob does not pop up when

released, contact a qualified service person

or gas supplier for repairs.

6. With control knob pressed in, push down

and release ignitor button (see Figure 19).

This will light pilot. The pilot is attached to

the front of burner. The pilot can be seen

through the glass panel. If needed, keep

pressing ignitor button until pilot lights.

Note:

If pilot does not stay lit, refer to

Troubleshooting, page 19. Also contact a

qualified service person or gas supplier for

repairs. Until repairs are made, light pilot

with match. To light pilot with match, see

Manual Lighting Procedure, page 16.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob.

• If control knob does not pop up when

released, contact a qualified service person

or gas supplier for repairs.

Note:

If pilot goes out, repeat steps 3

through 7. This heater has a safety interlock

system. Wait one (1) minute before lighting

pilot again.

8. Turn control knob counterclockwise

to desired heating level. The main burner

should light. Set control knob to any heat

level between 1 and 5.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

OPERATING HEATER

Continued

Figure 19 - Control Knob In The OFF

Position (Piezo Ignitor Shown)

Ignitor Button

Control Knob

Figure 20 - Pilot (actual pilot may vary)

Ignitor Electrode

Pilot Burner

Thermocouple

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise

to the

PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on these models

differs from standard thermostats. Standard

thermostats simply turn on and off the burner.

The thermostat used on this heater senses the

room temperature. The thermostat adjusts the

amount of gas flow to the burner. This increases

or decreases the burner flame height. At times

the room may exceed the set temperature. If so,

the burner will shut off. The burner will cycle

back on when room temperature drops below

the set temperature. The control knob can be set

to any heat level between 1 and 5. Selecting the

5 setting will cause the burner to remain fully on

without modulating down in most cases.
Note:

The thermostat sensing bulb measures

the temperature of air near the heater cabinet.

This may not always agree with room tem-

perature (depending on housing construction,

installation location, room size, open air tem-

peratures, etc.). Frequent use of your heater will

let you determine your own comfort levels.