Troubleshooting

If a problem still remains after applying the suggested remedies, contact your EIZO representative.

No picture

Problem

Possible cause and remedy

1. No picture

• None of the operation buttons light up.

• Check whether the power cord is connected properly.
• Turn the main power switch on.
• Turn off the main power, and then turn it on again a

few minutes later.

• Only the button lights up orange.

• Press .

• All of the operation buttons light up orange.

• Adjust the brightness (brilliance) of the screen.
• Operate the mouse or keyboard.
• Check whether the PC is turned on.

2. The message below appears.

This message appears when the signal is not input
correctly even when the monitor functions properly.

• This message appears when no signal is

input.
Example:

• The message shown left may appear, because some

PCs do not output the signal soon after power-on.

• Check whether the PC is turned on.
• Check whether the signal cable is connected properly.

• The message shows that the input signal is

out of the specified frequency range. (Such
signal frequency is displayed in magenta.)
Example:

fD: Dot clock

(Displayed only during digital signal input)

fH: Horizontal scan frequency
fV: Vertical scan frequency

• Check whether the PC is configured to meet the

resolution and vertical scan frequency requirements
of the monitor. (“Compatible Resolutions” in the Setup
Manual.)

• Reboot the PC.
• Select an appropriate display mode using the

graphics board’s utility. Refer to the manual of the
graphics board for details.