For propane/LP units, the installer must supply

an external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11" and 14" of

water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down

as shown in Figure 13. Pointing the vent down

protects it from freezing rain or sleet.

CAUTION: Use only new, black

iron or steel pipe. Internally-tinned

copper tubing may be used in

certain areas. Check your local

codes. Use pipe of 1/2" diameter

or greater to allow proper gas vol-

ume to heater. If pipe is too small,

undue loss of volume will occur.

Installation must include an equipment shutoff valve,

union, and plugged 1/8" NPT tap. Locate NPT tap

within reach for test gauge hook up. NPT tap must

be upstream from heater (see Figure 14).
IMPORTANT:

Install equipment shutoff valve

in an accessible location. The equipment shutoff

valve is for turning on or shutting off the gas to

the appliance.

Check your building codes for any special re-

quirements for locating equipment shutoff valve

to fireplaces.

Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged heater valves.

INSTALLATION

Continued

Figure 13 - External Regulator With Vent

Pointing Down (propane/LP gas only)

Propane/LP
Supply Tank

External
Regulator

Vent
Pointing
Down

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories, page 25.

** Minimum inlet pressure for purpose of input

adjustment.

Figure 14 - Gas Connection

Gas Control

3" Minimum

CSA Design-
Certified
Equipment Shutoff
Valve With 1/8"
NPT Tap*

Approved Flexible Gas Hose
(if allowed by local codes)

Pipe

Tee

Nipple Cap Joint

Sediment Trap

Natural Gas
From Gas Meter
(5" W.C.** to 10.5" W.C.
Pressure)
Propane/LP Gas
From External Regulator
(11" W.C.** to 14" W.C.
Pressure)

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install sediment trap in

supply line as shown in Figure 14. Locate sediment

trap where it is within reach for cleaning. Install

in piping system between fuel supply and heater.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into

heater controls. If sediment trap is not installed or

is installed wrong, heater may not run properly.

CAUTION: Avoid damage to

control. Hold fitting with wrench

when connecting it to gas piping

and/or fittings.