beautypg.com

Installation – Desa VYM27NR User Manual

Page 12

background image

www.desatech.com

108382-01G

12

INSTALLATION

Continued

IMPORTANT:

Make sure the heater burner is level.

If heater is not level, heater will not work properly.
Installation Items Needed

• hardware package (provided with heater)

• approved flexible gas hose (not provided) (if

allowed by local codes)

• sealant (resistant to propane/LP gas, not

provided)

• electric drill with 3/16" drill bit (metal or ma-

sonry as applicable)

• flathead screwdriver

1. Apply pipe joint sealant lightly to male

threads of the fitting to be threaded into gas

control. Connect approved flexible gas hose

to gas control fitting in heater (see Figure 11).

IMPORTANT:

Hold gas fitting with wrench

when connecting flexible gas hose.

2. Locate two masonry screws in hardware package.

3. Place heater base in fireplace.

4. Place logs in their proper position on heater

base. See Installing Logs, page 15.

5. Center heater base and logs front-to-back and

side-to-side in fireplace.

6. Carefully remove logs without moving heater

base.

7. Mark screw locations through one hole on each

side of the mounting bracket (see Figure 12).

If installing in a brick-bottom fireplace, mark

screw locations in mortar joint of bricks.

8. Remove heater base from fireplace. If install-

ing optional control accessories, do so at this

time. Follow all directions provided with

accessory.

9. Drill holes at marked locations using 3/16"

drill bit.

10. Attach base assembly to fireplace floor using

two masonry screws (in hardware package).

Fitting

Flexible Gas
Hose (if allowed
by local codes)

Figure 11 - Attaching Flexible Gas Hose

to Heater

Figure 12 - Attaching Base Assembly to

Fireplace Floor

Masonry
Screw

Mounting
Flanges

CONNECTING TO GAS SUppLY

WARNING: A qualified service

person must connect heater to gas

supply. Follow all local codes.

WARNING: Never connect

propane/LP heater directly to the

propane/LP supply. This heater

requires an external regulator

(not supplied). Install the exter-

nal regulator between the heater

and propane/LP supply.

WARNING: Never connect

natural gas heater to private (non-

utility) gas wells. This gas is com-

monly known as wellhead gas.

Installation Items Needed

Before installing heater, make sure you have the

items listed below.

• external regulator (for propane/LP units only,

supplied by installer)

• piping (check local codes)

• sealant (resistant to propane/LP gas)

• equipment shutoff valve *

• test gauge connection *

• sediment trap

• tee joint

• pipe wrench

* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 25.