Digi-Star EZ 2000/V User Manual
Page 8

Digi-Star Model EZ2000/EZ2000V
2. System operation
6
WEIGH AVERAGING
Press
key to assign the RM operation to the
FUNCTION key.
Press the
key twice within three seconds to
perform the weigh averaging operation.
The COUNT or number of weight values added to the
weigh memory will be displayed first. Then the
message AVERAG is displayed, followed by the
average weight value.
To print the average weight value, press the
key while the average weight is still displayed.
Average weight print sample shown below:
10JA00 12:01P
5CT 1258LB AV
TO PRINT: (OPTIONAL FEATURE)
Press the
key. Scale data will be sent to the
printer.
The weight will be printed automatically whenever
the TR is used.
Sample output format shown below:
10JA00 12:01P
123456LB GR
REMOTE DISPLAY (OPTION)
A Remote Display is available for viewing weights
at convenient locations. The Remote Display
includes a visual alarm light which can be used
with the TR option listed below.
TR OPTION: RADIO CONTROL
The transmitter/Receiver (TR) option uses a small
hand held transmitter to allow the operator to
remotely control the scale. The TR option allows
the operator to perform TARE and GROSS
functions.
RM
9850
1258
1
2
2×