Assembled bar and bracket assemblies, wide view, Indicator and hopper, How to use a scale on a central fill system – Digi-Star AGCO - White 8816 User Manual
Page 7

Scale Bracket and Load Cell Mounting Installation
D3879-US – Rev B
AGCO – White – 8800/8500 Series
5
Assembled Bar and Bracket Assemblies, Wide View
Indicator and Hopper
How to Use a Scale on a Central Fill System
The example uses 2000 lbs of seed evenly filled in both hoppers. There is 25 lbs of seed left from the last fill.
1. Push the ‘Start’ button. The screen will show zero, and the arrow is now pointing to ‘Net’ on the screen.
This is a temporary zero point to start loading the planter with seed. Next, fill 1000 lbs of seed into the
left hopper.
2. Push the ‘Stop’ button. The readout will read 1025 lbs of seed inventory.
3. Push the ‘Start’ button again. The screen will say zero again. Load another 1000 lbs of seed into the
right side.
4. Now push ‘Stop’ and the screen will read 2025 lbs of seed. The numbers will work lower as the seed is
planted.