DFI EC300 Series User Manual
Page 97

97
5
Ports and Connectors
EC300/310/320/321-CR6G60
JP1
JP2
JP5
JP8
COM 3
(JP1)
COM 4
(JP2)
COM 5
(JP5)
COM 6
(JP8)
1-2 On: RS232
(default)
3-4 On: RS422
Full Duplex
5-6 On: RS485
6
4
2
5
3
1
JP1 (for COM 3), JP2 (for COM 4), JP5 (for COM 5) and JP8 (for COM 6) are used
to confi gure the COM ports to RS232, RS422 (Full Duplex) or RS485.
The pin function of the COM ports will vary according to the jumper’s setting.
JP1 / JP2 / JP5 / JP8
6
4
2
6
4
2
5
3
1
5
3
1
COM 3 / COM 4 / COM 5 / COM 6
DCD
TXD
RXD
DT
R
GND
1 2 3 4 5
RX+
TX+
RX
-
TX
-
GND
1 2 3 4 5
D
ATA
+
N.C.
D
ATA
-
N.C.
GND
1 2 3 4 5
COM 3 to COM 6 RS232/RS422/RS485 Select
6
8 9
7
DSR
CT
S
RT
S
RI
6
8 9
7
N.C.
N.C.
N.C.
N.C.
6
8 9
7
N.C.
N.C.
N.C.
N.C.
This manual is related to the following products: