Uniformly distribute loads.
Ensure loads are applied to 2 or more lift lines.
• Max. 1500 Pounds Total Applied Load Per Winch
• Maximum live load design capacity on each batten = 30 Pounds Per Linear Foot
• Do Not Concentrate Full-Capacity Point Loads on One Lift Line
Daktronics strongly recommend a thorough understanding of stage rigging practices
before any changes are made to batten loads. Many reference sources are available
that contain important information that will allow you to safely hang heavy loads
once you understand the limitations and dynamics of the materials used in rigging:
wire rope, pipe battens, etc.
2
The Vortek hoist system is a dead-haul system meaning that the load is not counter-
weighted. Each hoist can lift loads only up to the design capacity. Overloading
will result in electrical overload protection shut down of the hoist and possible
damage to rigging components.
Each hoist unit consists of an integral electric motor driven reducer, directly
coupled to a cable drum, which winds steel cables (wire ropes) leading over
sheaves installed within the hoist assembly and along the structural steel of the
building. The cables support battens for attaching the load. The battens can
be lowered to the lower hard struck limit to allow attachment of loads. Refer to
installation drawings for the exact location and dimensions.
Warning:
The VORTEK Batten Hoists are not designed to raise and
lower people. These hoists should NEVER be used for
this purpose.
03
MOTORIZED BATTEN HOISTS
02
BATTEN AND HOIST LOADING INFO