SPECIFICATIONS

GENERAL SPECIFICATIONS

OUTPUT SPECIFICATIONS

Input Voltage

36~75V

Voltage Accuracy

Typical ±1.5%

Switching Frequency

Typical 330KHz Line Regulation

Typical (balance load)

±0.2%

Isolation Voltage

In/Out 2250V Load & Cross Regulation

Typical (balance load)

±1%

Isolation Capacitance

Typical 1500

pF Ripple & Noise

Typical 40

mV

Isolation Resistance

Minimum 10M

Ohms Current Limits

Typical 150%

MTBF

Bellcore TBD

Over Voltage

Typical 133%

Size

(1.95”x1.55”x0.37”) 49.6 x 39.4 x 9.5mm Voltage Trim

+10%,

-10%


PART NUMBERING SYSTEM

L

48

D

B

120

01

P

S

F A

Type of

Product

Input

Voltage

Number of

Outputs

Product

Series

Output

Voltage

Output

Current

ON/OFF

Logic

Pin Length

Option Code

L - 2”x1.6”

48 -

36~75V

D - Dual

Output

B - Bipolar

Output

120 - 12V


01 - 1.25A

N - Negative
P - Positive

S - 0.190”
R - 0.170”

F- RoHS 6/6

(Lead Free)

Space - RoHS 5/6

A - Standard

Functions


MODEL LIST

MODEL NAME

INPUT

OUTPUT

Efficiency @ Full Load

L48DB12001PS A

36V~75V

1.2A

±

12.0V

1.25A

86%

MECHANICAL DRAWING Open Frame Version

CONTACT:

www.delta.com.tw/dcdc

USA:
Telephone:

East Coast: (888) 335 8201
West Coast: (888) 335 8208
Fax: (978) 656 3964
Email:

[email protected]

Europe:
Telephone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email:

[email protected]

Asia & the rest of world:
Telephone: +886 3 4526107 ext 6220
Fax: +886 3 4513485
Email:

[email protected]

WARRANTY

Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from
Delta.

Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor
for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice.