Installing a Cash/Credit Display

A rectangular opening must be provided to accommodate the Cash/Credit

display.

Consult the shop drawing for cutout dimensions.

1. Lift displays into the support structure. Figure 99 shows a display being

inserted into a support structure.

Note: Daktronics assumes no liability for display damage or injury resulting
from incorrect setup or incorrect
lifting methods.

2. Drill through the front flanges

of the cabinet to attach the
display to the base structure
using appropriate hardware
for site conditions, as shown in

Figure 100. Actual site demands
will dictate variances and
appropriate mounting methods.

Access Internal Cash/Credit Display Components

The door of Cash/Credit displays is secured by a screw (two screws secure the door on 2H displays).

1. Use a Phillips-head screwdriver to loosen the screw.

2. Open the door using the knob attached to the display face.

3. The power supply is attached inside the cabinet to the display’s backsheet, as shown in Figure 111, and its

location varies between display sizes.

Grounding

Like Fuelight displays, Cash/Credit displays do not require a local earth ground electrode.

CORNER GAS

UNL

REG

DSL

Figure 9: Inserting Display Into
Cabinet

Figure 10: Secure Display in Sign Structure

EARTH

GROUND

SERIAL #

LABEL A

LABEL B

LABEL C

Figure 11: Internal Component Locations