beautypg.com

Directed Electronics Model 690XV User Manual

Page 34

background image

31

© 2 0 0 3 d i r e c t e d e l e c t r o n i c s , i n c .

Panic mode een

naab

blleed

d/disabled with the ignition on: Some

states have laws against siren capability in a moving vehicle.

Forced passive arming oon

n or off: If your system is

programmed for passive arming and the forced passive

arming feature has been programmed on, the system will

passively arm after one hour, even if a protected entry has

been left open. This feature is useful if a door has been left

ajar when leaving the vehicle. Forced passive arming ensures

that the security system will be armed in every situation.

Automatic Engine Disable (AED) on or ooffff: The purpose of

this feature is to protect the vehicle from being stolen at all

times, regardless of whether or not the alarm is armed. If

AED is programmed on, the starter of the vehicle will be dis-

abled 30 seconds after the ignition is turned off. Once the

key is turned off, the LED will flash slowly (one-half its

normal armed rate) to indicate the AED arming cycle.

Thirty seconds later, the starter of the vehicle will be dis-

abled. To start the car, it will be necessary to disarm the

system with the transmitter. It is also possible to disarm the

AED feature by turning the ignition key to the RUN posi-

tion and pressing the Valet button the programmed number

of times. AED is disabled when the system is in Valet Mode.

note: When the system passively arms after one hour, the
entry point that has been left open, and anything con-
nected to the same zone, is bypassed and cannot trigger
the system. However, the remaining inputs to the system
are fully operational.