Window / Patio Door Kit Installation

Your window kit has been designed to fit most
standard “vertical” and “horizontal” window
applications. Now with the addition of a 3rd slider
section, (Fig.2b), it is possible to install this kit in a
patio door application (up to a maximum height of
80"). Please refer to Fig. 2, Fig. 2a, & Fig. 2b for
minimum and maximum openings. For vertical
window and/or patio door applications, multi-lock
positions are provided on the edge of each slider
section. Two lock screws are provided to secure
each sliding section in position. Fig. 2c.

Internal Water Tank Safety Feature

This unit is equipped with a fail-safe switch
mechanism which prevents the unit from condensing
water in the event the water tank is accidentally
displaced, and/or FULL with water. If this situation
occurs, the unit will signal 8 BEEPS and the
WATER FULL indicator light will flash red
continuously until the water tank is correctly
positioned and/or emptied.

NOTE: The fan motor will continue to operate
under this condition. This is normal, but no
cooling or dehumidifying will occur until the tank
is emptied and/or correctly installed (It may take
several minutes before the compressor resumes
normal operation).

Operating Instructions

Before Starting This Unit

1) Select a suitable location, making sure you have

easy access to an electrical outlet.

2) Install the Flexible Exhaust Hose and the

Adjustable Window/Patio Door Slider Kit as
depicted in Fig. 2, Fig. 2a or Fig. 2b.

NOTE: Step 2 is required only while using the
AIR CONDITIONER MODE

3) Plug the unit into a 115 V /60 Hz grounded

electrical outlet.
DO NOT USE A REGULAR
EXTENSION CORD.
If it is necessary to use an extension cord with
this unit, use an approved “air conditioner
extension cord only. (available at most local
hardware stores)

4) Make sure the Water Tank is correctly positioned

inside the cabinet otherwise the unit will not
operate. Fig. 4.

R

Water Full

I/O

MODE

TIMER

SWING

CLOCK

FAN

ON

OFF

Cool/Heat/Dry

TEMP./CL

OCK

ADJ.

Horizontal Window

Window Slider Kit
Minimum: 26

5

/

8

" (67.5 cm)

Maximum: 48

3

/

8

" (123 cm)

R

Water Full

I/O

MODE

TIMER

SWING

CLOCK

FAN

ON

OFF

Cool/Heat/Dry

TEMP./CL

OCK

ADJ.

Vertical

Window

Window Slider Kit
Minimum: 26

5

/

8

" (67.5 cm)

Maximum: 48

3

/

8

" (123 cm)

Fig. 2

Fig. 2a

R

Water Full

I/O

MODE

TIMER

SWING

TEMP.

CLOCK

FAN

Cool/Heat/Dry

Patio

Door

Patio Door Kit
Minimum: 26

5

/

8

" (67.5 cm)

Maximum: 80" (203 cm)

Fig. 4

Fig. 2b

Fig. 2c