Physical Parameters

Product Reference Guide

1-7

Weighing

Specifications for scale capacity, settling time, minimum and maximum
static weight, zeroing, and warm-up time are given below. For more infor-
mation regarding the topic:

Proper Weighing Technique

, refer to the

Opera-

tion and Maintenance

chapter of this manual.

Rated Weight Capacity

The scale’s operational weight capacity is:

30.00 pounds, displayed in 0.01 increments

OR

15.000 kilograms

1

, displayed in 0.005 increments.

Minimum Increment

The minimum weight that can be accurately measured by the scale is 0.02
lb. (0.005 kg).

Maximum Static Weight (Overload)

A maximum static weight of 150 pounds (68 kg) can be sustained by the
scale without incurring damage or degrading performance.

Automatic Zero Maintenance

The scale’s software constantly monitors and adjusts the Zero point as
long as the deviation is within acceptable limits

2

, while compensating for

any debris accumulation or removal. During power-up, the scale automat-
ically re-zeros after verifying that all subsystems are functional. Addition-
ally, the scale may be manually “zeroed” by pushing the Scale Zero Push
Button located on the top of the vertical enclosure.

1. The scale can also be set for 9.99 kg max.
2. Acceptable limitis of deviation are set at -0.2 to +0.6 pounds (-0.078kg to 0.23kg), which is -0.67 to

+2.0% of total capacity.