beautypg.com

Datalogic Scanning 9500 User Manual

Page 448

background image

F-6

Magellan

®

9500

EAN-13

Check digit must be included in label data and is assumed to be cor-
rect

Prefix must be an ASCII character 'F'- total length including prefix
must be 14

Example: 'F1101234567891'

EAN-13 with 2-Digit Supplemental

Check digit must be included in label data and is assumed to be cor-
rect

Supplemental data is appended to base label

Prefix must be an ASCII character 'F'- total length including prefix
must be 16

Example: 'F110123456789112'

EAN-13 with 5-Digit Supplemental

Check digit must be included in label data and is assumed to be cor-
rect.

Prefix must be an ASCII character 'F'- total length including prefix
must be 19.

Example: 'F110123456789112345'.

EAN-13 with Code 128 Supplemental

Check digit must be included in label data and is assumed to be cor-
rect

Supplemental data is appended to base label

Prefix must be an ASCII character 'F'- total length including prefix
must be greater or equal to 20 (code 128 Supplemental codes are
variable length having a minimum of 2 data characters)

Characters immediately following base label must be of the form
'8100', '8101' or '8102'

Example: 'F11012345678918100000951'