Datalogic Scanning 9500 User Manual
Page 455

Product Reference Guide
F-13
Codabar
•
Check character must be included in label data.
•
Label length including check character and excluding prefix charac-
ters must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.
•
Prefix must be ASCII characters ']F0'.
•
Start stop character sets must meet the matching requirement set
forth by the scanner configuration item
•
Start stop character sets s must be of the form ABCD/ABCD and
must be included in the label.
•
Example: ']F0s$99.95s' (the lower case ‘s’ at each end of the example
is a placeholder for the start stop character set).
MSI/Plessey
•
Check character must be included in label data.
•
Label length including check character and excluding prefix charac-
ters must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.
•
Prefix must be ASCII characters ']M0'.
•
Example: ']M0144769254'.
Code 93
•
Prefix must be ASCII characters ']G0'.
•
Label length excluding prefix characters must meet requirements
imposed by the main scanner's fixed or variable label length control
for this symbology type.
•
Example : ']G0Code93-test'.