beautypg.com

Ia500, Administrator guide 4 wiring diagram – Code Blue IA500-S SINGLE BUTTON ANALOG SURFACE MOUNT User Manual

Page 5

background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-144-E

page 5 of 17

IA500

Administrator Guide

4 Wiring Diagram

IA500 SERIES PCB

RELAY

OUT

RN
G

TIP

Relay Output can be used to trigger an optional strobe as shown. Another

application for this output would be a door control system.

Refer to the IA500 programming manual for options.

See Relay Ratings

Below

INFO

SPKR

HELP

32 Ohm

Optional

12V DC

Power Supply

(Supplied by Others)

GRD

NEUTRAL

LOAD

Always use a

phone line surge

suppressor for

protection.

28 – 50 mA Loop Current required

To analog telephone service

If loop current is found to be less

than ideal, use either a Ring Voltage

Booster or a Long Loop Adaptor

Ref: Proctor 46222

Optional Strobe

40197

12V DC @ 180ma

Product wiring diagram reasonably represents current offering and is intended to assist in component identification and service. Earlier product production may have different

components and wiring connections. Reference the model and serial number from the unit ID tag and contact manufacturer to confirm replacement part version and availability.

CONTRACT FORM

2 FORM C

Contract Rating

Maximum Switching Power

30W (resistive)

62.5 VA (resistive)

Maximum Switching Voltage

220V DC

250V AC

Maximum Switching Current

1A

Maximum Carrying Current

2A (@20

0

C)

RELAY RATINGS