beautypg.com

Ia500, Administrator guide 3 getting started – Code Blue IA500-S SINGLE BUTTON ANALOG SURFACE MOUNT User Manual

Page 4

background image

Code Blue

259 Hedcor Street

Holland, MI 49423 USA

800.205.7186

www.codeblue.com

GU-144-E

page 4 of 17

IA500

Administrator Guide

3 Getting Started

1. The analog phone line will terminate on the barrier strip at Tip and Ring positions.

a. Talk voltage: 24~48

b. Loop Current Range: 27~50mA

2. Relay: The phone has one relay that can be a straight contact closure or supply low

current through the relay to power a remote strobe.

a. Spec Rating: 1A @ 220V DC or 250V AC (EA2-3TNU.1)

The IA500 series phones are remotely programmed. This enables the installer or end user to pro-

gram the unit from a phone on site or from a remote location.

3.1 Construction

Surface Mount

The IA500 housing shall be constructed of 16 gauge stainless steel and measure 7.375” W x 7.125”

H x 2” D and weigh approximately 5 lbs. The housing shall consist of two pieces, permitting the

backplate to be mounted during the rough in and the faceplate installed during completion. The back

shall have four holes for mounting hardware.

Flush Mount

The IA501 faceplate shall be constructed of 12 gauge stainless steel and the flush mounting box of

14 gauge painted steel. It shall measure 9” H x 9” W x 3.5” D and weigh approximately 9 lbs. The

faceplate shall provide an overlap to the mounting box to eliminate additional trim work.