Interconnecting le-1 and be-1 remote input plates, Dc power, Le-1 installation guide v1.0 4 – Cloud Electronics LE-1 User Manual
Page 4
LE-1 Installation Guide v1.0
4
LE-1
OUTPUT
LINK
LE-1
OUTPUT
LINK
LE-1
OUTPUT
LINK
LE-1
OUTPUT
LINK
LE-1
OUTPUT
LINK
To DCM-1
Extension Ports
(one per zone).
ZONE 1
ZONE 2
Additional
input plates
Additional
input plates
Interconnecting LE-1 and BE-1 remote input plates
The Cloud BE-1 is an alternative optional remote line input plate, providing a balanced
stereo line input on XLR connectors. LE-1 plates may be intermixed with BE-1s in a
daisy-chain wiring arrangement in the manner described for LE-1s alone, using the BE-
1’s OUTPUT and LINK connectors. All the plates on a chain will be treated as a single
line input at the DCM-1.
Note that is not possible to intermix LE-1s with Cloud ME-1 remote microphone input
plates in this manner.
DC Power
The LE-1 is powered from the DCM-1’s EXTENSION PORTs via the CAT-5 connection.
The LE-1 consumes 22mA of current on both the +12V and -12V rails from the DCM-1
power supply.
If there is any doubt regarding the DCM-1’s spare DC power capacity (as might be the
case in a very large system with many CDR-1 remote controls, level restoration relays,
etc.), please refer to page 53 of the DCM-1 Installation and User Guide where full
details of the DCM-1’s PSU ratings can be found.
Should you have any questions concerning the installation and connection of the LE-1,
please contact our Technical Support staff (details on front cover).