Cloud Electronics CXL-400T User Manual
Power ratings
CXL Series
100/70 V Transformers
Abridged Installation Guide
Applicable to types:
CXL-40T, CXL-100T, CXL-200T, CXL-400T
Thank you for purchasing this Cloud product.
The CXL Series of transformers are designed to interface a power amplifier’s low-impedance
output to a 100 V-line or 70 V-line loudspeaker system. They are not intended for any other
purpose.
IMPORTANT: This document provides abridged installation notes only. Full guidance on installing
CXL Series transformers can be found in the Installation Guide supplied with the Cloud rack trays
Models CXL-800 and CXL-1600. If you intend to install this transformer without a Cloud rack
tray, and do not have experience in wiring high voltage transformers, we strongly recommend that
you download the full manual fr
Power ratings
The numerical part of the product reference refers to the maximum power rating of the amplifier
channel that the transformer should be used with:
Type
For use with amplifiers with a
power rating (into 4 ohms) of:
CXL-40T
50 W per channel
CXL-100T
120 W per channel
CXL-200T
240 W per channel
CXL-400T
400 W per channel
Check the per-channel power rating in the amplifier’s User Guide to ensure the transformer is the
appropriate type.
CXL Series transformers are designed to be mounted on Cloud CXL-800 or CXL-1600 trays,
which can be 19” rack-mounted. While the use of these trays is recommended, independent
mounting is possible providing that due attention is paid to the safety issues noted overleaf.