Current consumption, Cdi-s200 serial interface card continued – Cloud Electronics CX263 User Manual
Page 16

Table of Jumper and Switch settings for music function controls
The table above shows the possible combinations for control of the music functions on the
CX263, based on the rear panel switches for each zone and the jumpers J19-24 that determine
which aspect of the system controls source selection in each zone. The music level control will
always be determined by the switches, the jumpers will only effect the source selection.
Details on how to operate the CX263 via the CDI-S200 interface are provided in the module
manual. The manual will arrive with the module, but can also be requested from
[email protected] if lost.
Current Consumption:
The CX263 can provide up to 80mA of power to internal modules. If this limit is exceeded, the
unit will eventually overheat and then shutdown. The current consumed by a CDI-S200 card is
34mA.
CX263 Zone Mixer
Installation and Setup Guide
CLOUD ELECTRONICS LIMITED
10
V2 100904
CDI-S200 Serial Interface Card continued
CX263
SW
SW
FR
DG
J19-24 SETTINGS
ACC
BYP
J4-6 SETTINGS
FR/SW
Jumper
DG/SW
Jumper
DIG/AN
Switch
FR/REM
Switch
Source
Control
Level
Control
N/A
N/A
N/A
FR
Front panel
Front panel
SW
SW
AN
REM
RSL-6
RSL-6
SW
N/A
DIG
REM
CDI-S200
CDI-S200
SW
DG
AN
REM
CDI-S200
RSL-6/RL-1
FR
N/A
AN
REM
Front panel
RSL-6/RL-1
FR
N/A
DIG
REM
Front panel
CDI-S200