Jumper and default settings summary, Technical specifications – Cloud Electronics PM12 User Manual
Page 33
PM4/8/12/16 Installation and User Guide v2.2
33
Jumper and default settings summary
Jumper
Purpose
Default
J1
Chime Select; +1
ON
J2
Chime Select; +2
OFF
J3
Chime Select; +4
OFF
J4
Digital Paging Interface termination
ON
J5
Chime On/Off
ON
J6
Internal Chime On/Off
ON
J7
NVM Reset
OFF
J8
High Priority
OFF
J9
Lock Groups
OFF
J10
Auto-reset zone selection
ON
J11
Zone Offset; +1
OFF
J12
Zone Offset; +2
OFF
J13
Zone Offset; +4
OFF
J14
Zone Offset; +8
OFF
Technical Specifications
Microphone
Capsule Type
Condenser
Polar Pattern
Cardioid
Zones
Number of Zones
4, 8, 12, 16
Chime
Number of Chimes
4, with Internal Speaker
Interface
Digital
Cloud Digital Paging Interface (RJ45)
Analogue
Zone Access Output (Short to Ground)
Audio Output
Power input
9 - 17 VAC, 12 - 24 VDC
Current
consumption
72 mA (4 zone), 83 mA (8 zone), 95 mA (12 zone), 107 mA (16 zone)
Dimensions
(mm)
PM
245 wide x 65 high (less gooseneck mic) x 170 deep
Gooseneck length
300 (standard); 140 (alternative Part No. MI100166)
Net Weight (kg)
1.2