Current considerations – Cloud Electronics PM12 User Manual
Page 15
PM4/8/12/16 Installation and User Guide v2.2
15
recommended cable length between the Cloud host mixer and the “last”
PM should not exceed 50 m. If longer cable lengths are required, then an
external PSU should be connected to the PM.
2.
Via the Analogue Port. The PM’s analogue interface allows for DC power.
The ‘+V’ and ‘0V’ terminals of the internal port connector should be wired
to the ‘+V’ and ‘0V’ pins respectively of the access connector at the Cloud
host mixer. This method of powering requires an additional core in
the access cable (the ‘0V’ connection will need to be made in any case for
the zone selection to function). Only one microphone may be powered
from the mixer in this way.
The wiring diagram on page 19 illustrates this
connection.
Current considerations
The table below gives the current required by the various PM models:
PM Model
Required Current
PM4
72 mA
PM8
83 mA
PM12
95 mA
PM16
107 mA
The following table shows spare DC current available from various Cloud host
mixers, etc., for powering additional items:
Host
Available Current
DCM-1
650 mA
Z4ii
120 mA
Z8ii
190 mA
CX163
Use ext. PSU
CX263
Use ext. PSU
36/50
Use ext. PSU
46/50
80 mA
These figures apply to the host units without any active options installed, such as
internal Bose
®
EQ cards or remote plates. These options all consume power, so the
available current may be insufficient to power the PM. In such cases, an external PSU
must be used.