Ventilation heights, Clearances – Dometic RM2652 User Manual

Page 3

background image

3

5. VENTILATION HEIGHTS

Refer to FIG 1., Page 2

Installation with roof

Minimum Ventilation

vent and lower side vent

heights in:

REFRIGERATOR

INCHES

MM

RM2652

57-3/4

1465

RM2852

63-3/4

1620

LOWER VENT CUTOUT

UPPER VENT CUTOUT

5-1/2"

21-9/16"

13-3/4"

23-3/4"

NOTE: All cutout dimensions are +/– 1/8".

6. CLEARANCES

Minimum clearances in inches to combustible materials are:

G:

Top

0"

K:

Side

0"

L:

Bottom

0"

M:

Rear

0"

N:

See NOTE

NOTE: Clearance "M" is between the rearmost part of the
refrigerator and the wall behind the refrigerator.

NOTE: Clearance "N" is the distance between the bottom
of the lower vent to the roof material. For ventilation
height, refer to

Section A. Installation, Item 5. Ventilation

Heights. See FIGS. 1 & 2.

FIG. 2

FIG. 3

NOTE: Wood Strip
MUST be in Place

Refrigerator

Overall

Recess

Total

Model

Dimensions

Dimensions

Ref. Vol.

Height

Width

Depth

Height

Width

Depth

A

B

C

H

W

D

Cu. Ft.

54-9/16

24-11/16

24-7/8

53-3/4

23-11/16

24

6.0

1386

627

632

1365

601

608

60-5/8

24-11/16

24-7/8

59-15/16

23-11/16

24

7.3

1530

627

632

1522

602

610

RM2652 (Inches)

(mm)

RM2852 (Inches)

(mm)