Ventilation heights, Clearances – Dometic RM2652 User Manual
Page 3

3
5. VENTILATION HEIGHTS
Refer to FIG 1., Page 2
Installation with roof
Minimum Ventilation
vent and lower side vent
heights in:
REFRIGERATOR
INCHES
MM
RM2652
57-3/4
1465
RM2852
63-3/4
1620
LOWER VENT CUTOUT
UPPER VENT CUTOUT
5-1/2"
21-9/16"
13-3/4"
23-3/4"
NOTE: All cutout dimensions are +/– 1/8".
6. CLEARANCES
Minimum clearances in inches to combustible materials are:
G:
Top
0"
K:
Side
0"
L:
Bottom
0"
M:
Rear
0"
N:
See NOTE
NOTE: Clearance "M" is between the rearmost part of the
refrigerator and the wall behind the refrigerator.
NOTE: Clearance "N" is the distance between the bottom
of the lower vent to the roof material. For ventilation
height, refer to
Section A. Installation, Item 5. Ventilation
Heights. See FIGS. 1 & 2.
FIG. 2
FIG. 3
NOTE: Wood Strip
MUST be in Place
Refrigerator
Overall
Recess
Total
Model
Dimensions
Dimensions
Ref. Vol.
Height
Width
Depth
Height
Width
Depth
A
B
C
H
W
D
Cu. Ft.
54-9/16
24-11/16
24-7/8
53-3/4
23-11/16
24
6.0
1386
627
632
1365
601
608
60-5/8
24-11/16
24-7/8
59-15/16
23-11/16
24
7.3
1530
627
632
1522
602
610
RM2652 (Inches)
(mm)
RM2852 (Inches)
(mm)