beautypg.com

Gas transformations and adjustments – Caple C710G User Manual

Page 9

background image

9

GAS TRANSFORMATIONS AND ADJUSTMENTS

GAS TRANSFORMATIONS AND

ADJUSTMENTS

Replacing the nozzles

If the equipment is adjusted for a type of gas that

is different from the one available, it is necessary

to replace the burner nozzles.

The choice of the nozzles to replace must be

made according to the table of the “technical cha-

racteristics”.

Act as follows:

- Remove the racks and burners.

- by means of a straight spanner L, unscrew the

nozzle U (fig.6) and substitute it with the corre-

sponding one.

- tighten the nozzle strongly.

Adjusting the burners

The lowest flame point must always be properly

adjusted and the flame must remain on even if

there is an abrupt shift from the maximum to the

minimum position.

If this is not so, it is necessary to adjust the lowest

flame point as follows:

- start the burner up

- turn the tap up to the minimum position (small

flame)

- remove the knob from the tap rod

- introduce a flat-tip screwdriver C in the hole F or

near the tap rod (fig. 7-7A) and turn the by-pass

screw up to a proper adjustment of the lowest

flame point.

As regards G 30 gas burners, the by-pass screw

must be tightened completely.

7/A

6

7