Maintenance – Caple C710G User Manual
Page 10
10
MAINTENANCE
MAINTENANCE
Lubricating the taps
In case of tap hardening, it is necessary to
disassemble and grease it.
These are the operations to carry out:
- Unscrew the two screws that lock the head
flange of the tap.
- Lift the gas adjusting cone and carefully clean it
with gasoline or diluent.
- Spread a little high-temperature grease on it,
making sure that the gas holes are not
obstructed.
- Reassemble all of the parts with care.
Replacing the power supply cable
If the power supply cable should be replaced, it is
necessary to use a cable with a section of 3 x 0.75
mm2, type HO5VV-F or H05RR-F, complying with
the regulations in force.
The connection to the terminal board must be
effected as shown in fig. 9:
brown cable
L
(phase)
blue cable
N
(neutral)
green-yellow cable
(ground)
8