Adjusting of the minimum of the top burners
In the minimum position the flame must have a length of about 4 mm and must remain
lit even with a quick turn from the maximum position to that of minimum.
The flame adjustment is done in the following way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a thin screwdriver turn the screw F until adjustment is correct (fig. 3.6).
Normally for LPG, the regulation screw is tightened up.
F
Fig. 3.6