background image

BRONKHORST HIGH-TECH B.V.

page 18

9.17.044

4.4.2 Bellows valve


These valves are suited for low pressure or vacuum applications. The user should not disassemble this
model.

4.5 K

v

-value calculation


This calculation method can be used to determine the K

v

-value of the main orifice of a control valve.

Determine desired

p across valve.

p must be at least 50% of supply pressure

Kv-value

calculation

1000

p

K

m

v

Units:

flow

-

)

/h

(kg

m

density

-

(kg / m ) at 20 C

3

and 1 atm.

delta p

-

p(bard)

The orifice bore diameter can be determined by:

d 7.6 K

v

[mm]


For C2 type of valves the diameter of the orifice can be calculated as shown above or looked up in the graph
below.

v

2

v

2

H O =

customer

customer

H O

in which:

v

= volume flow

 =

density

10

4

10

3

10

1

10

-1

10

1

10

0

10

4

10

3

10

2

10

1

P (bar)

d = 0.1 mm

d = 0.37 mm

d = 0.3 mm

d = 0.2 mm

d = 0.14 mm

10

2

10

0

10

-2

O

H O (ml/h)

2

10

-1

10

1

10

0

d = 1.0 mm d = 0.7 mm

d = 0.5 mm

P max.

v

If liquids have viscosity’s >15 cs (water = 1 cs), the flat orifice and plunger type control mechanism cannot be
used. For measuring systems only check maximum possible viscosity with factory.

4.6 Calibration

procedure


All instruments are factory calibrated. For re-calibration or re-ranging contact supplier or factory.