Diverter cartridge change and cleaning – Blu Bathworks TSP421 User Manual
Page 9
2013-07
1 866 907 0122 blubathworks.com
®
8
MAINTENANCE
Diverter cartridge change and cleaning
To clean the filters:
•
Shut off the water supply to both inlets
•
Remove the lever (1), remove the grub screw (2) with 2.5mm /
1
/
8
” Alan key, remove the closure con-
trol knob (3).
•
Remove the chrome ring (6).
•
Unscrew flange (7) using 17mm / i¾" spanner.
•
Remove the diverter cartridge (8).
•
Before re-assembling cartridge clean its housing with wet cloth and grease “O” rings on cartridge.
•
Place the new cartridge, inserting the two pivots into the corresponding seats.
•
Fit the flange (7).
•
Fit the chrome ring (6).
•
Fit the element (5) and the screw (4).
•
Fit the closure control knob (3).
•
Fit the grub screw (2) and fit the lever (1).
See also other documents in the category Blu Bathworks For Home:
- BEP002 (7 pages)
- BCM4214 (6 pages)
- BCA971M (9 pages)
- BCA141MR (10 pages)
- BCT180 (6 pages)
- SA1810 (6 pages)
- BCS14N (10 pages)
- BCS18N (10 pages)
- BT8004B168 (10 pages)
- BT0408 (8 pages)
- BCZ915C X2 (13 pages)
- SA2018B (4 pages)
- SA1018C (4 pages)
- SB9250 (10 pages)
- SA3023 (5 pages)
- SA0208 (6 pages)
- SA0110 (7 pages)
- SA0507 (5 pages)
- LSeat-006 (12 pages)
- LF8004 (14 pages)
- LW6030 (11 pages)
- LB9030 (6 pages)
- TSP611 (7 pages)
- TSU611 (7 pages)
- TF500 (6 pages)
- TF800 (6 pages)
- TF514 (9 pages)
- TF260 (9 pages)
- TSP511 (11 pages)
- TSU510 (10 pages)
- TEP421 (20 pages)
- TSU431 (11 pages)
- TEE200 (19 pages)
- TSP101 (7 pages)
- TSU140 (13 pages)
- TEP131 (17 pages)
- TEU131 (17 pages)
- TSP141 (9 pages)
- TSP131 (10 pages)
- TSU101 (7 pages)
- TSU131 (10 pages)
- TSU141 (9 pages)
- TSP211 (6 pages)
- TSU211 (6 pages)