MAINTENANCE
Thermostatic cartridge change and cleaning
Through years of use, impurities and lime scale could restrict flow of water through the filters
of the cartridge.
To clean the filters:
•
Shut off the water supply to both inlets
•
Remove the lever (1), remove the grub screw (2) with 2.5mm /
1
/
16
” Alan key, remove the temperature
control knob (3) and temperature stop ring (4).
•
Remove the chrome ring (5) and the screw (6) with 3mm /
1
/
8
” Alan key.
•
Use the extension of the cartridge (7) like a device to unscrew the thermostatic cartridge (8). Unscrew
the cartridge using 30mm / 1
1
/
6
” spanner, wash filters (9) under running water or leave to soak in
vinegar or de-scalding agent.
•
Before re-assembling cartridge clean its housing with wet cloth and grease “O” rings on cartridge.
•
Re-assemble cartridge (8) into body and the extension (7).
•
Fit the screw (6) and chrome ring (5).
•
Fit the temperature stop ring (4) according to the drawing and turn spindle (A) until you reach required
temperature 38°C.
•
Fit the temperature control knob (3) and test that the maximum temperature is set at 43°C.
•
Fit the grub screw (2) and fit the lever (1).