Model 3vh22, Theory of operation, Product identification – Dayton 3VH22 User Manual
Page 3: Specifications, General safety information (continued)
Version B - For Reduction
G016.J
®
3
Model 3VH22
Dayton Operating Instructions and Parts Manual
LO
OFF
HI
MED
Theory of Operation
Figure 2 - Product Identification
Piezo Ignitor
Button
Valve
Inlet
Shell
Base
Control
Knob
Hose/Regulator
Assembly
Product Identification
Ignitor
Electrode
Burner
Tube
Thermocouple
Top
Specifications
Output
Minimum Fuel
Maximum Fuel
Size
Weight
Rating Btu/Hr
Fuel
Consumption
Consumption
L x W x H (Inches)
(pounds)
40,000 to 80,000
Propane
0.44 Gallons/Hour
0.87 Gallons/Hour
20 x 15 x 16
13 (Heater)
Vapor Only
1.86 Pounds/Hour
3.71 Pounds/Hour
16 x 15 x 20
17 (Shipping)
Maximum Supply
Minimum Supply
Min. Temperature
Manifold Pressure
Ignitor
Pressure to Regulator
Pressure to Regulator
Surrounding Air
(Inches of Water Column)
Gap (Inches)
200 psi
20 psi (for purposes
-20ºF (-29ºC)
18 (High)
0.195
of input adjustment)
23.8 (Low)
THE FUEL SYSTEM
The hose/regulator assembly attaches to
the propane gas supply. This provides fuel
to the heater.
THE IGNITION SYSTEM
The piezo ignitor lights the main burner.
THE AUTOMATIC CONTROL SYSTEM
This system causes the heater to shut
down if the flame goes out.
General Safety Information
(Continued)
• To prevent injury, wear gloves when
handling heater.
• Never attach duct work to heater.
• Do not alter heater. Keep heater in
its original state.
• Do not use heater if altered.
• Turn off propane supply to heater
when not in use.
• Use only original replacement parts.
This heater must use design-specific
parts. Do not substitute or use
generic parts. Improper replacement
parts could cause serious or fatal
injuries.