Dayton 2E510E User Manual
Page 11
11
Models 2E510E, 2E511E, 3E218E, and 3E219D
Dayton Operating Instructions and Parts Manual
104447
®
Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can
occur.
Preventative Maintenance Schedule
Fuel tank
Flush every 150-200 hours of operation or as needed
See Storing, Transporting, or Shipping,
above
Air output and
Replace every 500 hours of operation or once a year
See Air Output, Air Intake, and Lint
lint filters
Filters, page 6
Air intake filter
Wash and dry with soap and water every 500 hours of
See Air Output, Air Intake, and Lint
operation or as needed
Filters, page 6
Fuel filter
Clean twice a heating season or as needed
See Fuel Filter, page 7
Fan blades
Clean every season or as needed
See Fan, page 6
Motor
Not required/permanently lubricated
How Often
How To
Item
Storing Transporting, or
Shipping
NOTE: If shipping, transport companies
require fuel tanks to be empty.
1. Drain fuel tank.
NOTE: Some models have drain plug on
underside of fuel tank. If so, remove drain
plug to drain all fuel. If heater does not
have drain plug, drain fuel through fuel
cap opening. Be sure all fuel is removed.
2. Replace drain plug if provided.
3. If any debris is noted in old fuel, add
1 or 2 quarts of clean kerosene to
tank, stir, and drain again. This will
prevent excess debris from clogging
filters during future use.
4. Replace fuel cap or drain plug. Prop-
erly dispose of old and dirty fuel.
Check with local automotive service
stations that recycle oil.
5. If storing, store heater in dry place.
Make sure storage place is free of dust
and corrosive fumes.
IMPORTANT: Do not store kerosene over
summer months for use during next heat-
ing season. Using old fuel could damage
heater.