7

103425

OWNER’S MANUAL

INSTALLATION

WARNING: A qualified ser-

vice person must install heater.
Follow all local codes.

WARNING: Before installing

in a previously-used wood-burn-
ing fireplace, clean chimney flue
and firebox. Make sure flue is
free of any creosote. Creosote
will ignite if highly heated. A dirty
chimney flue may create and dis-
tribute soot within the house. In-
spect chimney flue for damage. If
damaged, operate heater with flue
damper closed.

WARNING: Seal any fresh air

vents or ash clean-out doors lo-
cated on floor or wall of fireplace.
If not, drafting may cause pilot
outage or sooting. Use a heat-
resistant sealant. Do not seal
chimney flue damper.

WARNING: Never install the

heater
• in a bedroom or bathroom un-

less installed as a vented ap-
pliance, see page 10

• in a recreational vehicle
• where curtains, furniture,

clothing, or other flammable
objects are less than 42 inches
from the front, top, or sides of
the heater

• in high traffic areas
• in windy or drafty areas

CAUTION: This heater creates

warm air currents. These currents
move heat to wall surfaces next to
heater. Installing heater next to
vinyl or cloth wall coverings or
operating heater where impurities
(such as tobacco smoke, aromatic
candles, cleaning fluids, oil or
kerosene lamps, etc.) in the air
exist, may discolor walls.

IMPORTANT:

Vent-free heaters add mois-

ture to the air. Although this is beneficial,
installing heater in rooms without enough
ventilation air may cause mildew to form
from too much moisture. See Air for Com-
bustion and Ventilation
, pages 4 through 6.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply
is not propane/LP, do not install heater. Call
dealer where you bought heater for proper
type heater.

NOTICE: State or local codes may
only allow operation of this appli-
ance in a vented configuration.
Check your state or local codes.

INSTALLATION AND
CLEARANCES

(Vent-Free Operation Only)

WARNING: Maintain the mini-

mum clearances. If you can, pro-
vide greater clearances from
floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE

CLEARANCE TO

COMBUSTIBLE MATERIALS

Log Size

Side Wall

Ceiling

18", 24", 30"

16"

42"

NOTICE: This heater is intended
for use as supplemental heat. Use
this heater along with your pri-
mary heating system. Do not in-
stall this heater as your primary
heat source. If you have a central
heating system, you may run
system’s circulating blower while
using heater. This will help circu-
late the heat throughout the
house. In the event of a power
outage, you can use this heater
as your primary heat source.

LOG SIZING REQUIREMENTS

Log

Minimum Firebox

Size

Height

Depth

Front

Width

18"

17"

14"

20"

24"

17"

14"

26"

30"

17"

14"

32"

Figure 4 - Minimum Clearance to Wall and
Ceiling

Carefully follow the instructions below. This
will ensure safe installation into a masonry,
UL127-listed manufactured fireplace, or
listed vent-free firebox.

Minimum Wall and Ceiling
Clearances (see Figure 4)

A. Clearances from the side of the

fireplace opening to any combustible
wall should not be less than 16 inches.

B. Clearances from the top of the fireplace

opening to the ceiling should not be less
than 42 inches.

42"

16"

Left and

Right Sides

Continued