103425

OWNER’S MANUAL

Pressure Testing Gas Supply
Piping System

Test Pressures In Excess Of 1/2 PSIG

1.

Disconnect heater and its individual
manual shutoff valve from gas supply
piping system. Pressures in excess of
1/2 psig will damage heater regulator.

2.

Cap off open end of gas pipe where
manual shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and manual shutoff
valve to gas supply. Check re-
connected fittings for leaks.

WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming show
a leak. Correct all leaks at once.

WARNING: Test all gas pip-

ing and connections for leaks
after installing or servicing. Cor-
rect all leaks at once.

CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
heater. See guidelines under

Con-

necting to Gas Supply, page 12.

CHECKING GAS
CONNECTIONS

INSTALLATION

Continued

ON

POSIT

O

POS

Figure 15 - Manual Shutoff Valve

Open

Closed

Manual
Shutoff
Valve

Manual
Shutoff
Valve

Propane/LP
Supply Tank

Thermostat Gas Valve or
Control Valve Location

Figure 16 - Checking Gas Joints

Test Pressures Equal To or Less Than
1/2 PSIG

1.

Close manual shutoff valve (see Fig-
ure 15).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

3.

Check all joints from propane/LP sup-
ply tank to manual shutoff valve (see
Figure 16). Apply mixture of liquid
soap and water to gas joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

Pressure Testing Heater Gas
Connections

1.

Open manual shutoff valve (see Fig-
ure 15).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from manual shutoff
valve to thermostat gas valve (thermo-
stat-controlled models) or control valve
(variably-controlled models) (see Fig-
ure 16). Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
pages 15 and 16 [Thermostat-
Controlled Models] or pages 16
and 17 [Variable Manually-
Controlled Models]). Check all other
internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas to
Appliance
, page 16 [Thermostat-Con-
trolled Models] or page 17
[Variable Manually-Controlled
Models]).

Continued