UNVENTED (VENT-FREE) GAS LOG HEATER

INSTALLING HEATER BASE
ASSEMBLY

WARNING: If installing in a

sunken fireplace, special care is
needed. You must raise the fire-
place floor to allow access to
heater control panel. This will in-
sure adequate air flow and guard
against sooting. Raise fireplace
floor with noncombustible mate-
rial. Make sure material is secure.

CAUTION: Do not pick up

heater base assembly by burn-
ers. This could damage heater.
Only handle base assembly by
grates.

WARNING: You must secure

this heater to fireplace floor. If
not, heater will move when you
adjust controls. Moving heater
may cause a gas leak.

INSTALLING DAMPER
CLAMP ACCESSORY FOR
VENTED OPERATION

Note:

When used as a vented heater, appli-

ance must be installed only in a solid-fuel
burning fireplace with a working flue and
constructed of noncombustible material.

If your heater is a manually controlled model,
you may use this heater as a vented product.
There are three reasons for operating your
heater in the vented mode.

1.

The fireplace does not meet the
clearance to combustibles requirements
for vent-free operation.

2.

State or local codes do not permit vent-
free operation.

3.

You prefer vented operation.

If reasons number 1 or 2 above apply to you,
you must permanently open chimney flue
damper. You must install the damper clamp
accessory (to order, see Accessories, page
28). This will insure vented operation (see
Figure 10). The damper clamp will keep
damper open. Installation instructions are
included with clamp accessory.

Area of Various Standard

Round Flues

Diameter (ins.)

Area (sq. ins.)

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Chimney

Minimum Permanent

Height (ft.) Flue Opening (sq. ins.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Damper

Damper
Clamp

Damper

Clamp

Damper

Damper

Manufactured Fireplace

Masonry Fireplace

Figure 10 - Attaching Damper Clamp

INSTALLATION

Continued

See chart below for minimum permanent
flue opening you must provide. Attach
damper clamp so the minimum permanent
flue opening will be maintained at all times.

IMPORTANT:

Make sure the heater burners

are level. If heater is not level, heater will not
work properly. For thermostat models, avoid
damage to thermostat bulb. Avoid nicks or
sharp bends in thermostat bulb wire. Keep
thermostat bulb in mounting bracket.

CAUTION: Do not remove the

metal data plates attached to the
heater base assembly. The data
plates contain important warranty
information.