2.2
Replacement of needle
Caution: risk of injury!
Switch off main switch.
Never replace needle while the main switch is on.
–
Loosen screw 1 and remove needle from the needle bar 2.
–
Insert new needle to the stop in the hole in the needle bar 2.
Caution!
The needle scarf must face away from the operator and towards the
hook.
–
Tighten screw 1.
1-9
2
1